Intraprocedural Acute Stent Thrombosis of Unusual Etiology

Stent thrombosis is a rare but potentially fatal complication of percutaneous coronary intervention (PCI), typically associated with a combination of factors, such as issues with the stent itself (poor expansion, malapposition), patient-associated factors (non-compliance with antiplatelet medication, hypercoagulability), and procedural issues (vascular injury, incomplete lesion coverage). This article presents two unique cases of acute stent thrombosis occurring within minutes of stent deployment, attributed to embolization of cotton fibers (lint) from surgical drapes and reused instruments. In both cases, thrombosuction revealed fibrous foreign material as the underlying cause. Despite the acute and severe presentation, timely intervention with repeated thrombosuction, intracoronary pharmacotherapy, and balloon dilatation successfully restored coronary flow to TIMI III flow (thrombolysis in myocardial infarction score). These cases underscore the importance of strict contamination control, the use of lint-free materials, and adherence to sterile techniques in catheterization labs. Enhanced awareness and preventive protocols can significantly reduce the incidence of such rare but serious complications.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-04
DOI
https://doi.org/10.7759/cureus.91601
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraprocedural Acute Stent Thrombosis of Unusual Etiology

Sritam Acharya, B Prakash, Tapan Kumar, Mandar Shah
Cureus
Coronary Interventions and Diagnostics
article

Intraprocedural Acute Stent Thrombosis of Unusual Etiology

Sritam Acharya, B Prakash, Tapan Kumar, Mandar Shah
article en

Abstract

Stent thrombosis is a rare but potentially fatal complication of percutaneous coronary intervention (PCI), typically associated with a combination of factors, such as issues with the stent itself (poor expansion, malapposition), patient-associated factors (non-compliance with antiplatelet medication, hypercoagulability), and procedural issues (vascular injury, incomplete lesion coverage). This article presents two unique cases of acute stent thrombosis occurring within minutes of stent deployment, attributed to embolization of cotton fibers (lint) from surgical drapes and reused instruments. In both cases, thrombosuction revealed fibrous foreign material as the underlying cause. Despite the acute and severe presentation, timely intervention with repeated thrombosuction, intracoronary pharmacotherapy, and balloon dilatation successfully restored coronary flow to TIMI III flow (thrombolysis in myocardial infarction score). These cases underscore the importance of strict contamination control, the use of lint-free materials, and adherence to sterile techniques in catheterization labs. Enhanced awareness and preventive protocols can significantly reduce the incidence of such rare but serious complications.

CureusVol. 17(9)
Tata Main Hospital (IN)
Openalex Percentile: Top 62%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.