This study investigates the response of n-type Low Gain Avalanche Detectors (nLGADs) to local ion beam irradiation with low-penetrating 1.285 MeV gallium ions, focusing on charge collection efficiency (CCE) and gain degradation. Using the Transient Current Technique (TCT), we present charge collection maps before and after local irradiation. A 404 nm blue laser was used in postcharacterization, with no signal detected in the damaged zones after irradiation, suggesting significant charge trapping. The results reveal a pronounced vulnerability of nLGADs, with significant gain loss observed at fluences as low as 4 × 10 9 ions/cm 2. This study confirms that a donor removal mechanism occurs at low fluences, and we hypothesize that this effect is linked to vacancy-mediated mechanism. Additionally, we report a global reduction in CCE, suggesting a long-range impact on electric field triggered by local defects. This phenomenon is referred to as the global gain quenching (GGQ). Simulations of the electric field provide further confirmation of GGQ's occurrence.

Authors

Publication Details

Published
2025-09-04
DOI
https://doi.org/10.36227/techrxiv.175699542.28031525/v1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gain Response and Ion Beam-Induced Donor Removal in nLGAD Detector: Global Gain Quenching

Ioana Pintilie, Andreo Crnjac, Jairo Villegas, E. Cabruja et al.
Particle Detector Development and Performance
article

Gain Response and Ion Beam-Induced Donor Removal in nLGAD Detector: Global Gain Quenching

Ioana Pintilie, Andreo Crnjac, Jairo Villegas, E. Cabruja, Miloš Manojlović, Neil Moffat, S. Hidalgo, G. Pellegrini
article en

Abstract

This study investigates the response of n-type Low Gain Avalanche Detectors (nLGADs) to local ion beam irradiation with low-penetrating 1.285 MeV gallium ions, focusing on charge collection efficiency (CCE) and gain degradation. Using the Transient Current Technique (TCT), we present charge collection maps before and after local irradiation. A 404 nm blue laser was used in postcharacterization, with no signal detected in the damaged zones after irradiation, suggesting significant charge trapping. The results reveal a pronounced vulnerability of nLGADs, with significant gain loss observed at fluences as low as 4 × 10 9 ions/cm 2. This study confirms that a donor removal mechanism occurs at low fluences, and we hypothesize that this effect is linked to vacancy-mediated mechanism. Additionally, we report a global reduction in CCE, suggesting a long-range impact on electric field triggered by local defects. This phenomenon is referred to as the global gain quenching (GGQ). Simulations of the electric field provide further confirmation of GGQ's occurrence.

CERN, Ministerio de Ciencia, Innovación y Universidades, European Commission, European Regional Development Fund, Agencia Estatal de Investigación
Openalex Percentile: Top 90%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.