Based-Performance Evaluation of Partial Staggered-Story RC Frame Building Considering Confinement Coefficients of Steel Tube-Reinforced Concrete Columns
Compared with conventional RC frame buildings, staggered-story frame buildings are prone to the formation of short columns due to the vertical staggering of beam members, which exerts an adverse impact on the seismic performance of the building. Therefore, steel tube-reinforced concrete (ST-RC) columns are usually adopted to address the issue of the insufficient ductility of short columns. For this purpose, to investigate the seismic performance of partial staggered-story RC frame buildings, an elastic–plastic model is established based on a specific practical building, with ST-RC columns installed in the staggered-story area. By varying the confinement coefficients of the ST-RC columns (1.087, 1.152, 1.224, and 1.307) and classifying the member-level performance states, the seismic performance of ST-RC columns in staggered-story buildings under different confinement coefficients is evaluated. The research results indicate the following: in the statistical analysis of the performance states of the positive sections of the ST-RC columns, the degree of damage of the ST-RC columns first decreases and then increases sharply with an increase in the confinement coefficient, and the member damage is minimized when the confinement coefficient is 1.224. In the statistical analysis of the performance states of the inclined sections of the ST-RC columns, the damage state of the ST-RC columns shows a decreasing trend as the confinement coefficient increases; when the confinement coefficients are 1.224 and 1.307, the ST-RC columns are completely in the elastic state. With an increase in the confinement coefficient, the shear force borne by the ST-RC columns first increases and then decreases, while the tensile strain and compressive strain generally show a decreasing trend. When the confinement coefficient is 1.224, the tensile strain and compressive strain of the ST-RC columns are the smallest. Therefore, when arranging ST-RC columns in staggered-story buildings, it is necessary to select an appropriate confinement coefficient according to the actual project conditions to maximize the ductility of the short columns.
Authors
- Qing Qin (ORCID: https://orcid.org/0000-0001-7167-5855)
- Long Guo (ORCID: https://orcid.org/0000-0002-8971-2615)
- Jing‐Zhong Tong (ORCID: https://orcid.org/0000-0003-3190-518X)
- En Wang (ORCID: https://orcid.org/0000-0001-8302-2376)
- Jianbo Liu
- Shuyun Zhang (ORCID: https://orcid.org/0000-0002-1528-1621)
Institutions
- Xi'an University of Science and Technology (CN)
- Modern Electron (United States) (US)
- Shanghai Xiandai Architectural Design (CN)
- Zhejiang Modern Architectural Design & Research Institute (CN)
Publication Details
- Journal
- Buildings
- Published
- 2025-09-04
- DOI
- https://doi.org/10.3390/buildings15173193
- Primary Topic
- Structural Load-Bearing Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00