Simulation and Finite Element Analysis of the Electrical Contact Characteristics of Closing Resistors Under Dynamic Closing Impacts

Closing resistors in ultra-high-voltage (UHV) gas-insulated circuit breakers (GCBs) are critical components designed to suppress inrush currents and transient overvoltages during switching operations. However, in practical service, these resistors are subjected to repeated mechanical impacts and transient electrical stresses, leading to degradation of their electrical contact interfaces, fluctuating resistance values, and potential failure of the entire breaker assembly. Existing studies mostly simplify the closing resistor as a constant resistance element, neglecting the coupled electro-thermal–mechanical effects that occur during transient events. In this work, a comprehensive modeling framework is developed to investigate the dynamic electrical contact characteristics of a 750 kV GCB closing resistor under transient closing impacts. First, an electromagnetic transient model is built to calculate the combined inrush and power-frequency currents flowing through the resistor during its pre-insertion period. A full-scale mechanical test platform is then used to capture acceleration signals representing the mechanical shock imparted to the resistor stack. These measured signals are fed into a finite element model incorporating the Cooper–Mikic–Yovanovich (CMY) electrical contact correlation to simulate stress evolution, current density distribution, and temperature rise at the resistor interface. The simulation reveals pronounced skin effect and current crowding at resistor edges, leading to localized heating, while transient mechanical impacts cause contact pressure to fluctuate dynamically—resulting in a temporary decrease and subsequent recovery of contact resistance. These findings provide insight into the real-time behavior of closing resistors under operational conditions and offer a theoretical basis for design optimization and lifetime assessment of UHV GCBs.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-09-04
DOI
https://doi.org/10.3390/en18174714
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and Finite Element Analysis of the Electrical Contact Characteristics of Closing Resistors Under Dynamic Closing Impacts

Guangdong Zhang, Xiao Wu, Yanyan Bao, Xiaofei Wang et al.
1 citations
Energies
Electrical Fault Detection and Protection
0.73
article

Simulation and Finite Element Analysis of the Electrical Contact Characteristics of Closing Resistors Under Dynamic Closing Impacts

Guangdong Zhang, Xiao Wu, Yanyan Bao, Xiaofei Wang, Hailong Wang, Kang Liu, Simeng Li, Zicheng Qiu
article en
1 citations

Abstract

Closing resistors in ultra-high-voltage (UHV) gas-insulated circuit breakers (GCBs) are critical components designed to suppress inrush currents and transient overvoltages during switching operations. However, in practical service, these resistors are subjected to repeated mechanical impacts and transient electrical stresses, leading to degradation of their electrical contact interfaces, fluctuating resistance values, and potential failure of the entire breaker assembly. Existing studies mostly simplify the closing resistor as a constant resistance element, neglecting the coupled electro-thermal–mechanical effects that occur during transient events. In this work, a comprehensive modeling framework is developed to investigate the dynamic electrical contact characteristics of a 750 kV GCB closing resistor under transient closing impacts. First, an electromagnetic transient model is built to calculate the combined inrush and power-frequency currents flowing through the resistor during its pre-insertion period. A full-scale mechanical test platform is then used to capture acceleration signals representing the mechanical shock imparted to the resistor stack. These measured signals are fed into a finite element model incorporating the Cooper–Mikic–Yovanovich (CMY) electrical contact correlation to simulate stress evolution, current density distribution, and temperature rise at the resistor interface. The simulation reveals pronounced skin effect and current crowding at resistor edges, leading to localized heating, while transient mechanical impacts cause contact pressure to fluctuate dynamically—resulting in a temporary decrease and subsequent recovery of contact resistance. These findings provide insight into the real-time behavior of closing resistors under operational conditions and offer a theoretical basis for design optimization and lifetime assessment of UHV GCBs.

EnergiesVol. 18(17)
Electric Power Research Institute (US), Xi'an Jiaotong University (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
Openalex Percentile: Top 24%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.