Effects of electrical current on the sliding damage behaviors of Au-plated Cu alloy pairs

Failure mechanisms of high-power electrical connectors operating under hot-swap conditions at currents spanning tens to hundreds of amperes (interfacial current densities spanning 10 1 –10 3 A/mm 2 ) have remained elusive. To address this problem, reciprocating sliding tests were performed on comparative Cu pairs and Au-plated Cu pairs under electrical currents ranging from 0 A to 20 A (interfacial current density spanning 0–2.0×10 3 A/mm 2 ). At low currents (0–10 A), the Au-plated layer reduced average COF from ∼0.6 (Cu pairs) to ∼0.2 (Au-plated Cu pairs), representing a 70% reduction. And surface resistance was lowered from ∼7 mΩ·mm 2 in Cu pairs to ∼0.6 mΩ·mm 2 in Au-plated Cu pairs, a 90% decrease. The wear rate of Au-plated Cu pairs (∼10 -5 mm 3 ·N -1 ·m -1 ) was an order of magnitude lower than that of Cu pairs (∼10 -4 mm 3 ·N -1 ·m -1 ), demonstrating excellent anti-wear performance. But at high currents (15–20 A), the COF and surface resistance of Au-plated Cu pairs became comparable to those of Cu pairs. This was primarily attributed to wear-induced degradation of the Au plating, where the Au content dropped below 5%, diminishing its protective effect. Notably, at 20 A, arcing occurred in Cu pairs, but no arcing was observed in Au-plated Cu pairs. This indicates that the Au-plated layer effectively suppressed arc generation even at high currents. Interfacial temperatures generated by Joule and arc heating could explain the observed wear behaviors. These results offer valuable references for designing damage-tolerant high-power electrical connectors, where Au plating can be strategically used to enhance reliability under varying current conditions.

Authors

Institutions

Publication Details

Journal
Journal of Materials Research and Technology
Published
2025-09-01
DOI
https://doi.org/10.1016/j.jmrt.2025.08.212
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of electrical current on the sliding damage behaviors of Au-plated Cu alloy pairs

Zhiyuan Qian, Yunpeng Gu, Bao Shangguan, Chenfei Song et al.
Journal of Materials Research and Technology
Electrical Contact Performance and Analysis
article

Effects of electrical current on the sliding damage behaviors of Au-plated Cu alloy pairs

Zhiyuan Qian, Yunpeng Gu, Bao Shangguan, Chenfei Song, Zhifei Ma, Xianjuan Pang, Na Li, Yongzhen Zhang, Huanhuan Lu, Xinkuo Ji
article en

Abstract

Failure mechanisms of high-power electrical connectors operating under hot-swap conditions at currents spanning tens to hundreds of amperes (interfacial current densities spanning 10 1 –10 3 A/mm 2 ) have remained elusive. To address this problem, reciprocating sliding tests were performed on comparative Cu pairs and Au-plated Cu pairs under electrical currents ranging from 0 A to 20 A (interfacial current density spanning 0–2.0×10 3 A/mm 2 ). At low currents (0–10 A), the Au-plated layer reduced average COF from ∼0.6 (Cu pairs) to ∼0.2 (Au-plated Cu pairs), representing a 70% reduction. And surface resistance was lowered from ∼7 mΩ·mm 2 in Cu pairs to ∼0.6 mΩ·mm 2 in Au-plated Cu pairs, a 90% decrease. The wear rate of Au-plated Cu pairs (∼10 -5 mm 3 ·N -1 ·m -1 ) was an order of magnitude lower than that of Cu pairs (∼10 -4 mm 3 ·N -1 ·m -1 ), demonstrating excellent anti-wear performance. But at high currents (15–20 A), the COF and surface resistance of Au-plated Cu pairs became comparable to those of Cu pairs. This was primarily attributed to wear-induced degradation of the Au plating, where the Au content dropped below 5%, diminishing its protective effect. Notably, at 20 A, arcing occurred in Cu pairs, but no arcing was observed in Au-plated Cu pairs. This indicates that the Au-plated layer effectively suppressed arc generation even at high currents. Interfacial temperatures generated by Joule and arc heating could explain the observed wear behaviors. These results offer valuable references for designing damage-tolerant high-power electrical connectors, where Au plating can be strategically used to enhance reliability under varying current conditions.

Journal of Materials Research and TechnologyVol. 38
Henan University of Science and Technology (CN), China Academy of Space Technology (CN)
Shanghai Science and Technology Development Foundation, National Natural Science Foundation of China, Natural Science Foundation of Henan Province
Openalex Percentile: Top 76%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.