EVALUATION OF THE ACCURACY AND PRECISION OF TWO STATIC COMPUTER-ASSISTED GUIDED SURGERY SYSTEMS: AN IN VITRO EXPERIMENTAL STUDY

Computer-guided surgery is an established technique in dentistry, with current research focusing on optimizing the three-dimensional positioning of implants to achieve superior esthetic and functional outcomes. The precision of implant placement is a critical factor for long-term success. This study aimed to compare the accuracy of two static guided surgery systems that differ primarily in their drill-guiding method, in an in vitro laboratory simulation. For the study, a mandibular arch model with four missing premolars was created. The surgery was planned using virtual planning software after acquiring images via cone-beam computed tomography and scanning the model. Twenty implants were placed in five models, with ten implants for each system evaluated. Group 1 utilized a system with a guide sleeve and a handle to direct the drills, while Group 2 used a system where the drills were guided directly by the sleeve, without the use of a handle. The final position of the implants was measured by scanning the models after placement and superimposing them with the virtual plan using metrology software. The mean deviations for Group 1 were 0.308 mm (mesio-distal), 0.361 mm (vestibulo-lingual), and 0.449 mm (vertical). The mean deviations observed in Group 2 were 0.119 mm (mesio-distal), 0.398 mm (vestibulo-lingual), and 0.342 mm (vertical). Although both systems demonstrated accuracy compatible with established clinical standards, a statistically significant difference in the mesio-distal deviation (p = 0.006) favored the system without a handle, suggesting that its design may contribute to greater implant positional stability. No statistically significant differences were observed in the vestibulo-lingual and vertical deviations. In conclusion, while both systems demonstrate high accuracy and are clinically acceptable, the static guided surgery system without a handle offers a significant advantage in the precision of mesio-distal implant positioning.

Authors

Publication Details

Journal
Aracê.
Published
2025-09-03
DOI
https://doi.org/10.56238/arev7n8-258
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF THE ACCURACY AND PRECISION OF TWO STATIC COMPUTER-ASSISTED GUIDED SURGERY SYSTEMS: AN IN VITRO EXPERIMENTAL STUDY

Emilli Lima Neves, Newton Sesma, Jenival Correa de Almeida Júnior, Eduardo Mukai et al.
Aracê.
Surgical Simulation and Training
article

EVALUATION OF THE ACCURACY AND PRECISION OF TWO STATIC COMPUTER-ASSISTED GUIDED SURGERY SYSTEMS: AN IN VITRO EXPERIMENTAL STUDY

Emilli Lima Neves, Newton Sesma, Jenival Correa de Almeida Júnior, Eduardo Mukai, Denis Henrique Dias Reghini, Fernando Mondini
article en

Abstract

Computer-guided surgery is an established technique in dentistry, with current research focusing on optimizing the three-dimensional positioning of implants to achieve superior esthetic and functional outcomes. The precision of implant placement is a critical factor for long-term success. This study aimed to compare the accuracy of two static guided surgery systems that differ primarily in their drill-guiding method, in an in vitro laboratory simulation. For the study, a mandibular arch model with four missing premolars was created. The surgery was planned using virtual planning software after acquiring images via cone-beam computed tomography and scanning the model. Twenty implants were placed in five models, with ten implants for each system evaluated. Group 1 utilized a system with a guide sleeve and a handle to direct the drills, while Group 2 used a system where the drills were guided directly by the sleeve, without the use of a handle. The final position of the implants was measured by scanning the models after placement and superimposing them with the virtual plan using metrology software. The mean deviations for Group 1 were 0.308 mm (mesio-distal), 0.361 mm (vestibulo-lingual), and 0.449 mm (vertical). The mean deviations observed in Group 2 were 0.119 mm (mesio-distal), 0.398 mm (vestibulo-lingual), and 0.342 mm (vertical). Although both systems demonstrated accuracy compatible with established clinical standards, a statistically significant difference in the mesio-distal deviation (p = 0.006) favored the system without a handle, suggesting that its design may contribute to greater implant positional stability. No statistically significant differences were observed in the vestibulo-lingual and vertical deviations. In conclusion, while both systems demonstrate high accuracy and are clinically acceptable, the static guided surgery system without a handle offers a significant advantage in the precision of mesio-distal implant positioning.

Aracê.Vol. 7(8)
Openalex Percentile: Top 62%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EVALUATION OF THE ACCURACY AND PRECISION OF TWO STATIC COMPUTER-ASSISTED GUIDED SURGERY SYSTEMS: AN IN VITRO EXPERIMENTAL STUDY — Emilli Lima Neves, Newton Sesma, et al. · Aracê. (2025) | TGRS Research Map | TGRS