Power Quality at Railway Traction Substations in Ukraine and Its Role in Power System Stability

This study analyzes power quality indicators in both direct current and alternating current traction systems, highlighting their impact on system performance and stability. The findings reveal that voltage level is a key determinant of system stability, with alternating current systems contributing to a more stable power supply due to their higher voltage capabilities. However, harmonic distortions in both alternating current and direct current systems present significant challenges, affecting metering accuracy, increasing energy losses, and interfering with protective mechanisms. While direct current systems provide superior voltage stability, alternating current systems offer greater flexibility and higher power capacity, albeit with inefficiencies caused by phase shifts and harmonic distortions. A comparative analysis of power quality indicators shows that direct current traction substations exhibit lower total harmonic distortion, better voltage balance, and a higher power factor compared to alternating current substations. However, alternating current systems demonstrate lower voltage deviation, making them more resilient in maintaining grid stability.

Authors

Institutions

Publication Details

Published
2025-06-24
DOI
https://doi.org/10.1109/iccep65222.2025.11143652
Primary Topic
Transportation Systems and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Quality at Railway Traction Substations in Ukraine and Its Role in Power System Stability

Denys Zemskyi, Marzio Barresi, А. В. Антонов, Dmytro Bosyi et al.
Transportation Systems and Safety
article

Power Quality at Railway Traction Substations in Ukraine and Its Role in Power System Stability

Denys Zemskyi, Marzio Barresi, А. В. Антонов, Dmytro Bosyi, Volodymyr Mazorchuk
article en

Abstract

This study analyzes power quality indicators in both direct current and alternating current traction systems, highlighting their impact on system performance and stability. The findings reveal that voltage level is a key determinant of system stability, with alternating current systems contributing to a more stable power supply due to their higher voltage capabilities. However, harmonic distortions in both alternating current and direct current systems present significant challenges, affecting metering accuracy, increasing energy losses, and interfering with protective mechanisms. While direct current systems provide superior voltage stability, alternating current systems offer greater flexibility and higher power capacity, albeit with inefficiencies caused by phase shifts and harmonic distortions. A comparative analysis of power quality indicators shows that direct current traction substations exhibit lower total harmonic distortion, better voltage balance, and a higher power factor compared to alternating current substations. However, alternating current systems demonstrate lower voltage deviation, making them more resilient in maintaining grid stability.

Ukrainian State University of Chemical Technology (UA), Politecnico di Milano (IT)
Openalex Percentile: Top 58%
Transportation Systems and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.