Magnetite-Based Surface Plasmon Resonance Sensor for Pseudomonas Bacteria Detection

Rapid and precise detection of Pseudomonas bacteria is essential for medical diagnostics, water quality monitoring, and environmental applications. In this study, we propose a highly sensitive plasmonic biosensor incorporating magnetite (Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>) into a gold (Au) grating-based structure to enhance detection performance. The finite element method (FEM) was implemented to examine the sensor’s loss spectrum, wavelength sensitivity (W<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf>) and amplitude sensitivity (A<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf>) across a refractive index (RI) ranging from 1.36 to 1.42. The results demonstrated that Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf> significantly enhanced the electric field intensity at the metal-dielectric interface, resulting in improved sensitivity and resolution. The proposed sensor achieved an exceptional W<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf> of 5000 nm/RIU with an ultra-low detection resolution of 2×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−7</sup> RIU, enabling accurate detection of Pseudomonas bacteria. A red shift in resonance wavelength was observed with increasing RI, confirming strong interactions between bacterial analytes and surface plasmon polaritons (SPPs). The Au layer thickness (D<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">au</inf>) was optimized at 65 nm for maximum sensitivity while A<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf> reached a peak of 76.4 RIU<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> at RI 1.41. The proposed Au/(Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>) sensor highlighted the superior performance of over existing optical sensors. These findings suggest that the proposed plasmonic biosensor holds great promise for real-time bacterial detection. Future work will focus on experimental validation and practical implementation to further establish its applicability in clinical and environmental biosensing.

Authors

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/mac64480.2025.11140387
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetite-Based Surface Plasmon Resonance Sensor for Pseudomonas Bacteria Detection

Yogendra Kumar Prajapati, Rupam Srivastava, Sarika Pal, Samta Gaur et al.
Advanced biosensing and bioanalysis techniques
article

Magnetite-Based Surface Plasmon Resonance Sensor for Pseudomonas Bacteria Detection

Yogendra Kumar Prajapati, Rupam Srivastava, Sarika Pal, Samta Gaur, Vinit Kumar
article en

Abstract

Rapid and precise detection of Pseudomonas bacteria is essential for medical diagnostics, water quality monitoring, and environmental applications. In this study, we propose a highly sensitive plasmonic biosensor incorporating magnetite (Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>) into a gold (Au) grating-based structure to enhance detection performance. The finite element method (FEM) was implemented to examine the sensor’s loss spectrum, wavelength sensitivity (W<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf>) and amplitude sensitivity (A<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf>) across a refractive index (RI) ranging from 1.36 to 1.42. The results demonstrated that Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf> significantly enhanced the electric field intensity at the metal-dielectric interface, resulting in improved sensitivity and resolution. The proposed sensor achieved an exceptional W<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf> of 5000 nm/RIU with an ultra-low detection resolution of 2×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−7</sup> RIU, enabling accurate detection of Pseudomonas bacteria. A red shift in resonance wavelength was observed with increasing RI, confirming strong interactions between bacterial analytes and surface plasmon polaritons (SPPs). The Au layer thickness (D<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">au</inf>) was optimized at 65 nm for maximum sensitivity while A<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">sn</inf> reached a peak of 76.4 RIU<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> at RI 1.41. The proposed Au/(Fe<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf>O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>) sensor highlighted the superior performance of over existing optical sensors. These findings suggest that the proposed plasmonic biosensor holds great promise for real-time bacterial detection. Future work will focus on experimental validation and practical implementation to further establish its applicability in clinical and environmental biosensing.

Motilal Nehru National Institute of Technology (IN), ITM University (IN), National Institute of Technology Uttarakhand
Openalex Percentile: Top 79%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.