Design and Analysis of Low Cost Non-Invasive Pacemaker Pulse Detection System

This paper presents a simulation based design and analysis a non-invasive pacemaker pulse detection system in biomedical application, that helps improves monitoring and follow-up of cardiac patients by sensing change in magnetic fields caused by current pulse in implanted pacemaker. The pacemaker senses the heart activities and accordingly generates periodic electrical pulses for pacing these activities. Although, it is very difficult to determine pacemaker performance and battery status without any surgery. Therefore, this demands development of an external non-invasive pacemaker pulse detection device for periodic monitoring of implanted pacemaker. While ECG (electrocardiogram) device can offer more specific information for real-time pulse monitoring of the pacemaker, however this can not be used for continuous pulse monitoring and tracking of pacemaker signal. Therefore, for accurate implanted pacemaker pulse timing identification, it needs a specific ECG device. The exact timing of the pacemaker pulses also helps in routine ECG interpretation and residual battery charge determination. This work highlights the possible outcome of continuous real-time monitoring of pacemaker pulses by measuring magnetic field variations caused by the induced current pulses. The detection system of bipolar (biventricular) wireless pulses is designed and implemented using Simulink. This work also captures the pulses of the pacemaker using a simulated inductive sensor block and stores them in a simulation-based file as a record for analyzing pacemaker conditions. The simulated results present that the rise time of the bipolar pacing pulses is reduced from 8 μsec to 2.255 μsec (71.8% reduction) in the response. This stimulation rate is measured accurately in real time, but electromagnetic interference causes false readings.

Authors

Institutions

Publication Details

Published
2025-06-27
DOI
https://doi.org/10.1109/mac64480.2025.11140470
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of Low Cost Non-Invasive Pacemaker Pulse Detection System

Kunvar Kant Patel, Vikas Pandey, Ravi Prakash Tewari, Rohini Srivastava et al.
ECG Monitoring and Analysis
article

Design and Analysis of Low Cost Non-Invasive Pacemaker Pulse Detection System

Kunvar Kant Patel, Vikas Pandey, Ravi Prakash Tewari, Rohini Srivastava, Basant Kumar
article en

Abstract

This paper presents a simulation based design and analysis a non-invasive pacemaker pulse detection system in biomedical application, that helps improves monitoring and follow-up of cardiac patients by sensing change in magnetic fields caused by current pulse in implanted pacemaker. The pacemaker senses the heart activities and accordingly generates periodic electrical pulses for pacing these activities. Although, it is very difficult to determine pacemaker performance and battery status without any surgery. Therefore, this demands development of an external non-invasive pacemaker pulse detection device for periodic monitoring of implanted pacemaker. While ECG (electrocardiogram) device can offer more specific information for real-time pulse monitoring of the pacemaker, however this can not be used for continuous pulse monitoring and tracking of pacemaker signal. Therefore, for accurate implanted pacemaker pulse timing identification, it needs a specific ECG device. The exact timing of the pacemaker pulses also helps in routine ECG interpretation and residual battery charge determination. This work highlights the possible outcome of continuous real-time monitoring of pacemaker pulses by measuring magnetic field variations caused by the induced current pulses. The detection system of bipolar (biventricular) wireless pulses is designed and implemented using Simulink. This work also captures the pulses of the pacemaker using a simulated inductive sensor block and stores them in a simulation-based file as a record for analyzing pacemaker conditions. The simulated results present that the rise time of the bipolar pacing pulses is reduced from 8 μsec to 2.255 μsec (71.8% reduction) in the response. This stimulation rate is measured accurately in real time, but electromagnetic interference causes false readings.

Motilal Nehru National Institute of Technology (IN)
Openalex Percentile: Top 63%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Analysis of Low Cost Non-Invasive Pacemaker Pulse Detection System — Kunvar Kant Patel, Vikas Pandey, et al. · (2025) | TGRS Research Map | TGRS