Power-Based Indices with Single Metering Sections for Responsibility Assessment of Disturbing Loads

The integration of smart grids and energy communities in modern distribution systems drives the need for robust power quality analyses, particularly regarding waveform distortions. The distortions pose challenges in responsibility assessment between utilities and customers, due to their complex spectral characteristics and time-varying nature. To address this issue, this paper presents a comparative analysis of single-point measurement metrics (indices) derived from powers in non-ideal conditions, expanding their scope to incorporate supraharmonics (SHs). SHs are voltage or current frequency components that extend beyond the traditional harmonic range, typically ranging up to 150 kHz. Also, a new variation index useful to quantify the incidence of supraharmonics on the power-based responsibility indices is provided. Utilizing laboratory measurements from an emulated low-voltage system, the metrics are assessed under conditions involving disturbing loads and utility background distortion. The paper provides a detailed critical analysis of power-based metrics, describes the laboratory setup, and presents and discusses the results of numerical applications.

Authors

Institutions

Publication Details

Published
2025-06-24
DOI
https://doi.org/10.1109/iccep65222.2025.11143656
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power-Based Indices with Single Metering Sections for Responsibility Assessment of Disturbing Loads

G. Carpinelli, Antonio Bracale, P. Caramia, Piotr Kuwalek
Structural Health Monitoring Techniques
article

Power-Based Indices with Single Metering Sections for Responsibility Assessment of Disturbing Loads

G. Carpinelli, Antonio Bracale, P. Caramia, Piotr Kuwalek
article en

Abstract

The integration of smart grids and energy communities in modern distribution systems drives the need for robust power quality analyses, particularly regarding waveform distortions. The distortions pose challenges in responsibility assessment between utilities and customers, due to their complex spectral characteristics and time-varying nature. To address this issue, this paper presents a comparative analysis of single-point measurement metrics (indices) derived from powers in non-ideal conditions, expanding their scope to incorporate supraharmonics (SHs). SHs are voltage or current frequency components that extend beyond the traditional harmonic range, typically ranging up to 150 kHz. Also, a new variation index useful to quantify the incidence of supraharmonics on the power-based responsibility indices is provided. Utilizing laboratory measurements from an emulated low-voltage system, the metrics are assessed under conditions involving disturbing loads and utility background distortion. The paper provides a detailed critical analysis of power-based metrics, describes the laboratory setup, and presents and discusses the results of numerical applications.

Parthenope University of Naples (IT), Poznań University of Technology (PL)
Openalex Percentile: Top 75%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power-Based Indices with Single Metering Sections for Responsibility Assessment of Disturbing Loads — G. Carpinelli, Antonio Bracale, et al. · (2025) | TGRS Research Map | TGRS