Visualization and Analysis of Perfusion Cluster Velocity From a Large Area Near-Infrared Image Sensor

Flexible, large area, image sensors (FLA-IS) can enable the capture of additional biomarkers not found in current wearable devices with discrete optical sensors (d-os). To demonstrate, this study utilizes an in-house, near-infrared sensitive FLA-IS system to collect data from multiple volunteers on a finger test site. A custom processing algorithm is applied to reveal subcutaneous perfusion movement and quantify that into a blood flow velocity equivalent biomarker: perfusion cluster velocity (PcV). The paper analyzes the variability and repeatability of all the processed signals by tracking features representing duration between selected points of interest (POI) for PcV and reference photoplethysmography (PPG) waveforms per cardiac cycle. The resulting analyses show 24% improvement in dynamic range and 20% less cycle-to-cycle variation for PcV, and PcV, PPG features compared to PPG-only features, demonstrating FLA-IS' potential for advanced biomarker measurements.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-09-04
DOI
https://doi.org/10.1109/lsens.2025.3606440
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visualization and Analysis of Perfusion Cluster Velocity From a Large Area Near-Infrared Image Sensor

Takao Someya, Yusaku Tagawa, Takashi Nakamura, Tomoyuki Yokota et al.
IEEE Sensors Letters
Spectroscopy Techniques in Biomedical and Chemical Research
article

Visualization and Analysis of Perfusion Cluster Velocity From a Large Area Near-Infrared Image Sensor

Takao Someya, Yusaku Tagawa, Takashi Nakamura, Tomoyuki Yokota, Chung-kai Chen, Xingle Wang, Gen Koide, Naoki Takada, Akihiko Fujisawa, Adithya Naresh
article en

Abstract

Flexible, large area, image sensors (FLA-IS) can enable the capture of additional biomarkers not found in current wearable devices with discrete optical sensors (d-os). To demonstrate, this study utilizes an in-house, near-infrared sensitive FLA-IS system to collect data from multiple volunteers on a finger test site. A custom processing algorithm is applied to reveal subcutaneous perfusion movement and quantify that into a blood flow velocity equivalent biomarker: perfusion cluster velocity (PcV). The paper analyzes the variability and repeatability of all the processed signals by tracking features representing duration between selected points of interest (POI) for PcV and reference photoplethysmography (PPG) waveforms per cardiac cycle. The resulting analyses show 24% improvement in dynamic range and 20% less cycle-to-cycle variation for PcV, and PcV, PPG features compared to PPG-only features, demonstrating FLA-IS' potential for advanced biomarker measurements.

IEEE Sensors LettersVol. 9(10)
Jikei University School of Medicine (JP), Tokyo University of Information Sciences (JP), Japan Display (Japan) (JP), The University of Tokyo (JP)
Openalex Percentile: Top 83%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visualization and Analysis of Perfusion Cluster Velocity From a Large Area Near-Infrared Image Sensor — Takao Someya, Yusaku Tagawa, et al. · IEEE Sensors Letters (2025) | TGRS Research Map | TGRS