Performance Analysis of Solar Air Heaters with Dimpled Roughness in Equilateral Triangular Ducts

Solar air heaters (SAHs) offer a practical and environmentally friendly method of harnessing solar energy. Enhancing the thermal performance of SAHs is critical, and various techniques, including surface modifications, have been explored. This experimental study investigates the influence of dimpled rib roughness on the thermal and hydraulic performance of a SAH with an equilateral triangular duct. The experiments were conducted over a range of operating conditions: relative roughness height (e/D) from 0.023 to 0.058, relative roughness pitch (L/e) from 3 to 9, relative roughness width (S/e) from 6 to 18, and Reynolds numbers from 6000 to 18000. The results indicate that the dimpled rib configuration significantly enhances heat transfer compared to smooth SAH. The maximum enhancement in the Nusselt number (Nu) and friction factor (f) is 5.78 and 2.26 times higher, respectively, than the smooth SAH. The highest performance enhancement criteria (PEC) value of 4.64 is achieved at e/D=0.058, L/e=3, and S/e=6. Additionally, empirical correlations for Nu and f were derived based on experimental data, providing valuable tools for SAH design optimization. This study demonstrates the potential of dimpled ribs to significantly improve SAH performance, making it a viable option for efficient solar energy utilization.

Authors

Institutions

Publication Details

Journal
Diyala Journal of Engineering Sciences
Published
2025-09-01
DOI
https://doi.org/10.24237/djes.2025.18313
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of Solar Air Heaters with Dimpled Roughness in Equilateral Triangular Ducts

Ammar A. Farhan, Hadeel Ahmed
Diyala Journal of Engineering Sciences
Heat Transfer Mechanisms
article

Performance Analysis of Solar Air Heaters with Dimpled Roughness in Equilateral Triangular Ducts

Ammar A. Farhan, Hadeel Ahmed
article en

Abstract

Solar air heaters (SAHs) offer a practical and environmentally friendly method of harnessing solar energy. Enhancing the thermal performance of SAHs is critical, and various techniques, including surface modifications, have been explored. This experimental study investigates the influence of dimpled rib roughness on the thermal and hydraulic performance of a SAH with an equilateral triangular duct. The experiments were conducted over a range of operating conditions: relative roughness height (e/D) from 0.023 to 0.058, relative roughness pitch (L/e) from 3 to 9, relative roughness width (S/e) from 6 to 18, and Reynolds numbers from 6000 to 18000. The results indicate that the dimpled rib configuration significantly enhances heat transfer compared to smooth SAH. The maximum enhancement in the Nusselt number (Nu) and friction factor (f) is 5.78 and 2.26 times higher, respectively, than the smooth SAH. The highest performance enhancement criteria (PEC) value of 4.64 is achieved at e/D=0.058, L/e=3, and S/e=6. Additionally, empirical correlations for Nu and f were derived based on experimental data, providing valuable tools for SAH design optimization. This study demonstrates the potential of dimpled ribs to significantly improve SAH performance, making it a viable option for efficient solar energy utilization.

Diyala Journal of Engineering Sciences
University of Baghdad (IQ)
Openalex Percentile: Top 76%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.