Fault-Tolerant Control of a Single-Phase Bidirectional Dual Active Bridge DC–DC Converter

Single-phase voltage-fed dual active bridge (DAB) converters have emerged as a prevalent topology for high-power isolated dc–dc conversion, facilitating bidirectional power flow in electric vehicle dc fast chargers (DCFC). An open-circuit fault (OCF) in power switches brings a significant risk to the functionality and safety of power electronics interfaces (PEI). In DAB converters, the OCFs can give rise to current stress, DC bias, and capacitor voltage instability. It can also saturate the transformer magnetic core, leading to device over-current. To overcome these issues, the faulty switch needs to be identified so that a fault-tolerant control can be employed to ensure the safe operation of the DAB converter. In this paper, a fault diagnosis technique to detect the fault and identify the faulty switch is explored, followed by developing an enhanced fault-tolerant control scheme. This approach needs low-bandwidth current monitoring solely based on one side of the transformer, providing both economic and design benefits. The proposed method can be executed without requiring any hardware modifications.

Authors

Institutions

Publication Details

Published
2025-06-24
DOI
https://doi.org/10.1109/iccep65222.2025.11143673
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-Tolerant Control of a Single-Phase Bidirectional Dual Active Bridge DC–DC Converter

Davide De Simone, Ali Arzani, Prashant Kumar, Satish M. Mahajan
Advanced DC-DC Converters
article

Fault-Tolerant Control of a Single-Phase Bidirectional Dual Active Bridge DC–DC Converter

Davide De Simone, Ali Arzani, Prashant Kumar, Satish M. Mahajan
article en

Abstract

Single-phase voltage-fed dual active bridge (DAB) converters have emerged as a prevalent topology for high-power isolated dc–dc conversion, facilitating bidirectional power flow in electric vehicle dc fast chargers (DCFC). An open-circuit fault (OCF) in power switches brings a significant risk to the functionality and safety of power electronics interfaces (PEI). In DAB converters, the OCFs can give rise to current stress, DC bias, and capacitor voltage instability. It can also saturate the transformer magnetic core, leading to device over-current. To overcome these issues, the faulty switch needs to be identified so that a fault-tolerant control can be employed to ensure the safe operation of the DAB converter. In this paper, a fault diagnosis technique to detect the fault and identify the faulty switch is explored, followed by developing an enhanced fault-tolerant control scheme. This approach needs low-bandwidth current monitoring solely based on one side of the transformer, providing both economic and design benefits. The proposed method can be executed without requiring any hardware modifications.

Tennessee Technological University (US), Politecnico di Milano (IT)
Appalachian Regional Commission
Openalex Percentile: Top 77%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.