Performance Assessment of ISOP LLC with Buck-Boost Post-Regulator and ISOP LLC-DAB
This paper provides a comparative efficiency analysis of two dc-dc topologies—LLC with non-inverting buck-boost post-regulator and LLC-DAB—by evaluating the losses of Gallium Nitride (GaN) HEMTs in both converter topologies. The study considers conduction, switching, gate driver, and reverse conduction losses to ensure a comprehensive comparison. Results demonstrate that the LLC-DAB topology achieves superior efficiency, particularly at full power, due to the Zero-Voltage Switching (ZVS) capability of the DAB stage, which minimizes switching losses and enhances the performance of the LLC modules. In contrast, the LLC with non-inverting buck-boost post-regulator topology exhibits higher efficiency at lower power levels but suffers from increased switching losses at full load due to its hard-switching operation.
Authors
- Andrea Volpini (ORCID: https://orcid.org/0000-0001-9849-4157)
- Pericle Zanchetta (ORCID: https://orcid.org/0000-0002-7830-1140)
- Giulia Tresca (ORCID: https://orcid.org/0000-0002-5710-3129)
- Filippo Gemma (ORCID: https://orcid.org/0000-0002-0111-1488)
Institutions
- University of Pavia (IT)
Publication Details
- Published
- 2025-06-24
- DOI
- https://doi.org/10.1109/iccep65222.2025.11143669
- Primary Topic
- Distributed and Parallel Computing Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00