A new method for non‐invasive determination of effective pulmonary blood flow and cardiac output in spontaneously breathing subjects

The differential Fick method is well established for measuring effective pulmonary blood flow (EPBF) and cardiac output (CO) but until now it has only been used for patients on mechanical ventilation. Here we present and evaluate a new approach adapted to spontaneous breathing situations. Ten healthy subjects with diverse anthropometric and respiratory parameters were studied in the sitting position. Rebreathing through a dead space of precisely known volume and recording the resulting rise in the end-tidal CO<sub>2</sub> value allowed the determination of EPBF. The shunted blood flow fraction was estimated from the arterial oxygen saturation to obtain cardiac output (FickCO). Two measurements were made on each subject 15 min apart. Reference values for cardiac output (RefCO), were calculated as the product of stroke volume and heart rate where the stroke volume was measured with established echocardiography techniques. Heart rate and arterial oxygen saturation were measured with an ordinary pulse oximeter. Comparing FickCO to RefCO using a Bland-Altman analysis, we obtained a mean bias of 0.03 L/min, limits of agreement (LoA) of +1.43 to -1.37 (95% CI) L/min and a percentage error (PE) of 0.25. For the mean of two FickCO observations, we obtained a mean bias of -0.04 L/min, LoA +0.94 to -1.01 (95% CI) and PE of 0.17. The differential Fick method can be adapted to spontaneously breathing situations with good absolute accuracy using simple equipment. Short data collection times make it possible to use the mean of repeated observations and thereby get adequate precision. The new method could therefore be of value both in the pre-operative and the post-operative setting.

Authors

Institutions

Publication Details

Journal
Experimental Physiology
Published
2025-09-04
DOI
https://doi.org/10.1113/ep093079
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new method for non‐invasive determination of effective pulmonary blood flow and cardiac output in spontaneously breathing subjects

David Patrickson, Andras Gedeon, J-H Jansson, Mats Wallin
Experimental Physiology
Hemodynamic Monitoring and Therapy
article

A new method for non‐invasive determination of effective pulmonary blood flow and cardiac output in spontaneously breathing subjects

David Patrickson, Andras Gedeon, J-H Jansson, Mats Wallin
article en

Abstract

The differential Fick method is well established for measuring effective pulmonary blood flow (EPBF) and cardiac output (CO) but until now it has only been used for patients on mechanical ventilation. Here we present and evaluate a new approach adapted to spontaneous breathing situations. Ten healthy subjects with diverse anthropometric and respiratory parameters were studied in the sitting position. Rebreathing through a dead space of precisely known volume and recording the resulting rise in the end-tidal CO<sub>2</sub> value allowed the determination of EPBF. The shunted blood flow fraction was estimated from the arterial oxygen saturation to obtain cardiac output (FickCO). Two measurements were made on each subject 15 min apart. Reference values for cardiac output (RefCO), were calculated as the product of stroke volume and heart rate where the stroke volume was measured with established echocardiography techniques. Heart rate and arterial oxygen saturation were measured with an ordinary pulse oximeter. Comparing FickCO to RefCO using a Bland-Altman analysis, we obtained a mean bias of 0.03 L/min, limits of agreement (LoA) of +1.43 to -1.37 (95% CI) L/min and a percentage error (PE) of 0.25. For the mean of two FickCO observations, we obtained a mean bias of -0.04 L/min, LoA +0.94 to -1.01 (95% CI) and PE of 0.17. The differential Fick method can be adapted to spontaneously breathing situations with good absolute accuracy using simple equipment. Short data collection times make it possible to use the mean of repeated observations and thereby get adequate precision. The new method could therefore be of value both in the pre-operative and the post-operative setting.

Experimental PhysiologyVol. 111(3)
Stockholm University (SE), Karolinska Institutet (SE), Mindconnect (Sweden) (SE), Optronic (Sweden) (SE), Street Smart Equipment (Sweden) (SE)
Openalex Percentile: Top 62%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.