High-Power Density Three-Phase Inverter with 3D Circuit Structure Using Liquid Immersion Cooling

Recently, the power density of power converters has increased to minimize their size and weight. However, this increase in power density also leads to higher heat generation density and maximum temperature of converters. Therefore, conventional cooling methods, such as air cooling and indirect water cooling, may not be sufficient to cool high-power density power converters. Liquid immersion cooling has been considered as an effective solution for cooling data center servers. This study aimed to design a high-power density three-phase inverter using a liquid immersion cooling system. The cooling system used hydrofluoroether (HFE) as a refrigerant. The inverter was designed with a 3D circuit structure to maximize superior cooling and dielectric strength of HFE, achieving a power density of 245 kVA/L. The cooling performance of the system was verified via computational fluid dynamics (CFD) thermal analysis. The simulation results indicated that the maximum temperature reached 65.4◦C, which is well below the rated value of the switching devices. Furthermore, in experimental heat generation tests with actual equipment, the maximum temperature reached 46.2◦C, which was also well below the rated value of the switching devices.

Authors

Institutions

Publication Details

Journal
IEEJ Journal of Industry Applications
Published
2025-09-04
DOI
https://doi.org/10.1541/ieejjia.25000258
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Power Density Three-Phase Inverter with 3D Circuit Structure Using Liquid Immersion Cooling

Noriya Izu, Daiki Satou
IEEJ Journal of Industry Applications
Heat Transfer and Optimization
article

High-Power Density Three-Phase Inverter with 3D Circuit Structure Using Liquid Immersion Cooling

Noriya Izu, Daiki Satou
article en

Abstract

Recently, the power density of power converters has increased to minimize their size and weight. However, this increase in power density also leads to higher heat generation density and maximum temperature of converters. Therefore, conventional cooling methods, such as air cooling and indirect water cooling, may not be sufficient to cool high-power density power converters. Liquid immersion cooling has been considered as an effective solution for cooling data center servers. This study aimed to design a high-power density three-phase inverter using a liquid immersion cooling system. The cooling system used hydrofluoroether (HFE) as a refrigerant. The inverter was designed with a 3D circuit structure to maximize superior cooling and dielectric strength of HFE, achieving a power density of 245 kVA/L. The cooling performance of the system was verified via computational fluid dynamics (CFD) thermal analysis. The simulation results indicated that the maximum temperature reached 65.4◦C, which is well below the rated value of the switching devices. Furthermore, in experimental heat generation tests with actual equipment, the maximum temperature reached 46.2◦C, which was also well below the rated value of the switching devices.

IEEJ Journal of Industry ApplicationsVol. 14(6)
Tokyo Denki University (JP)
Openalex Percentile: Top 76%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.