A vision transformer framework for arrhythmia classification with spectrogram augmented time-frequency transformed ECG signals

Abstract Models using raw electrocardiogram (ECG) signals for the classification of cardiac arrhythmias do not extract significant spectral information essential to detect complex arrhythmias. Time-frequency (TF) transforms can efficiently describe the spectral-temporal information. However, current methods, which place greater emphasis on local dependencies, are not effective in extracting complex spectral-temporal features. In addition, imbalanced databases result in biased models, decreasing the detection rate of rare arrhythmias of clinical importance. In this work, we propose a novel multi-head self-attention (MHSA) Vision Transformer (ViT) framework (MHSA-ViT-TF) that uses TF representations of raw ECG beats and TF masking augmentation for cardiac arrhythmia classification. The ViT model uses MHSA to retrieve rich contextual and spatial features from time-frequency images. We employed continuous wavelet transform (CWT), short-time Fourier transform (STFT), and Mel-scaled spectrogram TF representations and compared the performance of the ViT model with imbalanced data. Furthermore, TF masking was applied to STFT spectrograms to address class imbalance, a comparatively less investigated approach in ECG signal analysis. We tested the performance of the proposed MHSA-ViT-TF model using the MIT-BIH arrhythmia database and the St. Petersburg INCART 12-lead arrhythmia database. The experimental findings proved that the integration of STFT spectrograms with TF masking augmentation and the ViT classification model produced a prominent performance compared to the state-of-the-art techniques with 99.56 ± 0.9% accuracy, precision of 99.56 ± 0.9%, recall of 99.56 ± 0.9%, and an F-score of 99.56 ± 0.9% using the MIT-BIH arrhythmia database for the seven classes of arrhythmias considered. The relative improvement with balanced data enhanced with spectrograms is 0.66%. We presented the attention maps, presenting the input image regions considered in the final model predictions. Furthermore, the proposed MHSA-ViT-TF model also demonstrated consistent performance using balanced data, achieving an accuracy of 99.50% on the St. Petersburg INCART 12-lead arrhythmia database.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2025-09-04
DOI
https://doi.org/10.1088/2631-8695/ae038c
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A vision transformer framework for arrhythmia classification with spectrogram augmented time-frequency transformed ECG signals

R. V., Shylaja Rahula
1 links
Engineering Research Express
ECG Monitoring and Analysis
article

A vision transformer framework for arrhythmia classification with spectrogram augmented time-frequency transformed ECG signals

R. V., Shylaja Rahula
article en

Abstract

Abstract Models using raw electrocardiogram (ECG) signals for the classification of cardiac arrhythmias do not extract significant spectral information essential to detect complex arrhythmias. Time-frequency (TF) transforms can efficiently describe the spectral-temporal information. However, current methods, which place greater emphasis on local dependencies, are not effective in extracting complex spectral-temporal features. In addition, imbalanced databases result in biased models, decreasing the detection rate of rare arrhythmias of clinical importance. In this work, we propose a novel multi-head self-attention (MHSA) Vision Transformer (ViT) framework (MHSA-ViT-TF) that uses TF representations of raw ECG beats and TF masking augmentation for cardiac arrhythmia classification. The ViT model uses MHSA to retrieve rich contextual and spatial features from time-frequency images. We employed continuous wavelet transform (CWT), short-time Fourier transform (STFT), and Mel-scaled spectrogram TF representations and compared the performance of the ViT model with imbalanced data. Furthermore, TF masking was applied to STFT spectrograms to address class imbalance, a comparatively less investigated approach in ECG signal analysis. We tested the performance of the proposed MHSA-ViT-TF model using the MIT-BIH arrhythmia database and the St. Petersburg INCART 12-lead arrhythmia database. The experimental findings proved that the integration of STFT spectrograms with TF masking augmentation and the ViT classification model produced a prominent performance compared to the state-of-the-art techniques with 99.56 ± 0.9% accuracy, precision of 99.56 ± 0.9%, recall of 99.56 ± 0.9%, and an F-score of 99.56 ± 0.9% using the MIT-BIH arrhythmia database for the seven classes of arrhythmias considered. The relative improvement with balanced data enhanced with spectrograms is 0.66%. We presented the attention maps, presenting the input image regions considered in the final model predictions. Furthermore, the proposed MHSA-ViT-TF model also demonstrated consistent performance using balanced data, achieving an accuracy of 99.50% on the St. Petersburg INCART 12-lead arrhythmia database.

Engineering Research ExpressVol. 7(3)
Jawaharlal Nehru Technological University, Hyderabad (IN), Vignana Jyothi Institute of Management (IN), University of Hyderabad (IN)
Openalex Percentile: Top 63%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.