Impact of Inspiratory Pressure Rise Time on Lung-Emptying in Time Controlled Adaptive Ventilation

<b>Background:</b> The airway pressure release ventilation (APRV)-based time controlled adaptive ventilation (TCAV) protocol can potentially minimize ventilator-induced lung injury (VILI). Inspiratory pressure rise time (IPRT) is a parameter available in pressure-controlled ventilation modes, yet its role within TCAV remains unclear. We hypothesized that varying IPRTs impact lung emptying and associated ventilatory parameters (driving pressure [ΔP], intrinsic PEEP [PEEPi], exhaled tidal volume [V<sub>Te</sub>]). <b>Methods:</b> This single-center, prospective exploratory study included 10 intubated subjects ventilated utilizing the TCAV protocol. Subjects underwent consecutive experimental trials with IPRTs of 500 and 1,000 ms, each preceded by a baseline (BL) with an IPRT of 0 ms. Analyzed parameters were ventilator-derived ΔP (ΔP<sub>vent</sub>), PEEPi, and V<sub>Te</sub>. Elastance (E<sub>RS</sub> = ΔP<sub>vent</sub>/V<sub>Te</sub>) and elastance-derived ΔP (ΔP<sub>elast</sub> = E<sub>RS</sub> × V<sub>Te</sub>) were calculated. End-expiratory lung volume (EELV) and end-inspiratory lung volume were assessed through electrical impedance tomography (EIT). <b>Results:</b> Prolonged IPRT increased ΔP<sub>elast</sub> compared with ΔP<sub>vent</sub> in each baseline/trial combination (ΔP<sub>vent</sub> 13.5 ± 1.5 cm H<sub>2</sub>O vs ΔP<sub>elast</sub> 18.4 ± 2.7 cm H<sub>2</sub>O at 1,000 ms IPRT, <i>P</i> < .001) through a loss of PEEPi. Conventional PEEPi measurements did not detect these changes. The EIT data showed a reduction in EELV during the trials. <b>Conclusions:</b> IPRT prolongation under TCAV reduced EELV/PEEPi, therefore increasing ΔP. Conventional PEEPi measurement methods are misleading in this context. We therefore suggest adding the recommendation to set IPRT to 0 ms for the TCAV protocol.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2025-10-08
DOI
https://doi.org/10.1177/19433654251359959
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Inspiratory Pressure Rise Time on Lung-Emptying in Time Controlled Adaptive Ventilation

Lars Reinhardt, Mascha O. Fiedler, Patrick Rehn, Werner Schmidt et al.
Respiratory Care
Respiratory Support and Mechanisms
article

Impact of Inspiratory Pressure Rise Time on Lung-Emptying in Time Controlled Adaptive Ventilation

Lars Reinhardt, Mascha O. Fiedler, Patrick Rehn, Werner Schmidt, Markus Weigand, Benjamin Neetz, Thomas G. Flohr, Nicole Kraus, Christoph Laußer
article en

Abstract

<b>Background:</b> The airway pressure release ventilation (APRV)-based time controlled adaptive ventilation (TCAV) protocol can potentially minimize ventilator-induced lung injury (VILI). Inspiratory pressure rise time (IPRT) is a parameter available in pressure-controlled ventilation modes, yet its role within TCAV remains unclear. We hypothesized that varying IPRTs impact lung emptying and associated ventilatory parameters (driving pressure [ΔP], intrinsic PEEP [PEEPi], exhaled tidal volume [V<sub>Te</sub>]). <b>Methods:</b> This single-center, prospective exploratory study included 10 intubated subjects ventilated utilizing the TCAV protocol. Subjects underwent consecutive experimental trials with IPRTs of 500 and 1,000 ms, each preceded by a baseline (BL) with an IPRT of 0 ms. Analyzed parameters were ventilator-derived ΔP (ΔP<sub>vent</sub>), PEEPi, and V<sub>Te</sub>. Elastance (E<sub>RS</sub> = ΔP<sub>vent</sub>/V<sub>Te</sub>) and elastance-derived ΔP (ΔP<sub>elast</sub> = E<sub>RS</sub> × V<sub>Te</sub>) were calculated. End-expiratory lung volume (EELV) and end-inspiratory lung volume were assessed through electrical impedance tomography (EIT). <b>Results:</b> Prolonged IPRT increased ΔP<sub>elast</sub> compared with ΔP<sub>vent</sub> in each baseline/trial combination (ΔP<sub>vent</sub> 13.5 ± 1.5 cm H<sub>2</sub>O vs ΔP<sub>elast</sub> 18.4 ± 2.7 cm H<sub>2</sub>O at 1,000 ms IPRT, <i>P</i> < .001) through a loss of PEEPi. Conventional PEEPi measurements did not detect these changes. The EIT data showed a reduction in EELV during the trials. <b>Conclusions:</b> IPRT prolongation under TCAV reduced EELV/PEEPi, therefore increasing ΔP. Conventional PEEPi measurement methods are misleading in this context. We therefore suggest adding the recommendation to set IPRT to 0 ms for the TCAV protocol.

Respiratory CareVol. 70(12)
Heidelberg University (DE), University Hospital Heidelberg (DE), Barmherzige Brüder Klinikum St. Elisabeth in Straubing (DE), Universitätsklinikum Würzburg (DE), German Center for Lung Research (DE)
Openalex Percentile: Top 66%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.