Haemolysis Generated with the Use of Glass Bottles Instead of PVC, DEHP-Free Blood Collection Bags in the Oxygen-Ozone Therapy

This study investigates the safety implications of using glass bottles versus PVC, DEHP-free plastic bags for autologous blood collection in major autohaemotherapy with oxygen-ozone (O 2 -O 3 -MAHT). Concerns have arisen regarding increased haemolysis when blood is collected in glass containers, particularly due to high shear stress, surface irregularities and turbulence associated with vacuum-based collection. Historical data from transfusion medicine already established that glass induces higher red blood cell (RBC) rupture rates, a finding confirmed through mathematical modelling and simulations in this study. The release of haemoglobin and formation of meta-haemoglobin, both pro-inflammatory mediators, pose potential risks to patient safety. The authors applied ordinary differential equations (ODEs) to model haemolysis, biochemical stability and inflammatory responses, revealing that plastic bags offer superior preservation of RBC integrity and reduce inflammation risks. Comparative data on foam formation, albumin adsorption and oxygenation efficacy further reinforce the advantage of plastic containers. Forecast modelling suggests that treatment failure and safety risks increase significantly with glass use, particularly at higher ozone doses. The study concludes that DEHP-free plastic bags provide a more reliable, safe and biocompatible method for O 2 -O 3 -MAHT and recommends phasing out glass bottles to minimize haemolysis and ensure the therapeutic efficacy of medical ozone procedures.

Authors

Institutions

Publication Details

Journal
MAEDICA – a Journal of Clinical Medicine
Published
2025-03-15
DOI
https://doi.org/10.26574/maedica.2025.20.2.257
Primary Topic
Medical and Biological Ozone Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Haemolysis Generated with the Use of Glass Bottles Instead of PVC, DEHP-Free Blood Collection Bags in the Oxygen-Ozone Therapy

Luigi Valdenassi, Salvatore Chirumbolo, Marianno Franzini
MAEDICA – a Journal of Clinical Medicine
Medical and Biological Ozone Research
article

Haemolysis Generated with the Use of Glass Bottles Instead of PVC, DEHP-Free Blood Collection Bags in the Oxygen-Ozone Therapy

Luigi Valdenassi, Salvatore Chirumbolo, Marianno Franzini
article en

Abstract

This study investigates the safety implications of using glass bottles versus PVC, DEHP-free plastic bags for autologous blood collection in major autohaemotherapy with oxygen-ozone (O 2 -O 3 -MAHT). Concerns have arisen regarding increased haemolysis when blood is collected in glass containers, particularly due to high shear stress, surface irregularities and turbulence associated with vacuum-based collection. Historical data from transfusion medicine already established that glass induces higher red blood cell (RBC) rupture rates, a finding confirmed through mathematical modelling and simulations in this study. The release of haemoglobin and formation of meta-haemoglobin, both pro-inflammatory mediators, pose potential risks to patient safety. The authors applied ordinary differential equations (ODEs) to model haemolysis, biochemical stability and inflammatory responses, revealing that plastic bags offer superior preservation of RBC integrity and reduce inflammation risks. Comparative data on foam formation, albumin adsorption and oxygenation efficacy further reinforce the advantage of plastic containers. Forecast modelling suggests that treatment failure and safety risks increase significantly with glass use, particularly at higher ozone doses. The study concludes that DEHP-free plastic bags provide a more reliable, safe and biocompatible method for O 2 -O 3 -MAHT and recommends phasing out glass bottles to minimize haemolysis and ensure the therapeutic efficacy of medical ozone procedures.

MAEDICA – a Journal of Clinical MedicineVol. 20(2)
University of Verona (IT), University of Pavia (IT)
Openalex Percentile: Top 74%
Medical and Biological Ozone Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Haemolysis Generated with the Use of Glass Bottles Instead of PVC, DEHP-Free Blood Collection Bags in the Oxygen-Ozone Therapy — Luigi Valdenassi, Salvatore Chirumbolo, et al. · MAEDICA – a Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS