Radiopaque marker impression and 3D Boolean inversion for metal artifact-distorted same-day implant planning: a digital workflow.

The present article describes a dental implant planning workflow to solve the CBCT artifact problem. The technique uses a radiopaque 3D-printed tray to take impressions and complete data alignment of the dental arches where implants are planned. From the impressions, 3D Boolean inversion is performed to obtain the surface mesh of teeth and virtually remove the undercut of dentition mesh before an implant surgical guide is designed. The trueness and precision of 3D alignment are then compared with the original radiographic template alignment using the double-scan method. In the present study, the results showed that this method could improve alignment trueness and allow for the elimination of radiographic template making, reducing patient visits and making possible a same-day guided implant surgery.

Authors

Publication Details

Journal
PubMed
Published
2025-09-01
DOI
https://doi.org/10.3290/j.ijcd.b6429781
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiopaque marker impression and 3D Boolean inversion for metal artifact-distorted same-day implant planning: a digital workflow.

Xin-Fang Leong, Shahida Mohd-Said, In Meei Tew, Chunxu Liu
1 citations
PubMed
Orthopaedic implants and arthroplasty
2.01
article

Radiopaque marker impression and 3D Boolean inversion for metal artifact-distorted same-day implant planning: a digital workflow.

Xin-Fang Leong, Shahida Mohd-Said, In Meei Tew, Chunxu Liu
article en
1 citations

Abstract

The present article describes a dental implant planning workflow to solve the CBCT artifact problem. The technique uses a radiopaque 3D-printed tray to take impressions and complete data alignment of the dental arches where implants are planned. From the impressions, 3D Boolean inversion is performed to obtain the surface mesh of teeth and virtually remove the undercut of dentition mesh before an implant surgical guide is designed. The trueness and precision of 3D alignment are then compared with the original radiographic template alignment using the double-scan method. In the present study, the results showed that this method could improve alignment trueness and allow for the elimination of radiographic template making, reducing patient visits and making possible a same-day guided implant surgery.

PubMedVol. 28(3)
Openalex Percentile: Top 12%
Orthopaedic implants and arthroplasty
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.