High-resolution computed tomography of two-dimensional beam profile using dual-axis rotating wire

The use of a wire probe is a robust method for beam profile measurement, but it can only provide a 1D projection of the beam profile. In this study, we developed a novel method for measuring a beam projected from a 360° angle by a dual-axis rotation of a wire and obtaining a complete 2D profile via image reconstruction. We conducted a proof-of-principle study using an Ar+ ion beam and optimized the reconstruction algorithm. The experimental results showed that the use of the order subsets expectation maximization algorithm is the most reasonable method, providing a highly accurate absolute 2D beam profile within a processing time on the millisecond scale. Furthermore, analysis of 2D profiles at different probing positions provided the beam direction and the phase-space distribution. This versatile method can be applied to various fields of particle beam technologies, such as particle therapy, semiconductor processing, and material analysis, as well as basic scientific research.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0271359
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution computed tomography of two-dimensional beam profile using dual-axis rotating wire

Ryuichi Takemasa, N. Nakajima, Y. Shiina, Y. Nakano et al.
Review of Scientific Instruments
Medical Imaging Techniques and Applications
article

High-resolution computed tomography of two-dimensional beam profile using dual-axis rotating wire

Ryuichi Takemasa, N. Nakajima, Y. Shiina, Y. Nakano, Ryo Ota, Hiroharu Tamaru
article en

Abstract

The use of a wire probe is a robust method for beam profile measurement, but it can only provide a 1D projection of the beam profile. In this study, we developed a novel method for measuring a beam projected from a 360° angle by a dual-axis rotation of a wire and obtaining a complete 2D profile via image reconstruction. We conducted a proof-of-principle study using an Ar+ ion beam and optimized the reconstruction algorithm. The experimental results showed that the use of the order subsets expectation maximization algorithm is the most reasonable method, providing a highly accurate absolute 2D beam profile within a processing time on the millisecond scale. Furthermore, analysis of 2D profiles at different probing positions provided the beam direction and the phase-space distribution. This versatile method can be applied to various fields of particle beam technologies, such as particle therapy, semiconductor processing, and material analysis, as well as basic scientific research.

Review of Scientific InstrumentsVol. 96(9)
Rikkyo University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 67%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.