[Design and analysis of human arm pathological tremor simulation system].

In order to characterize the characteristics of pathological tremor of human upper limb, a simulation system of pathological tremor of human arm was provided and its dynamic response was analyzed. Firstly, in this study, a two-degree-of-freedom human arm dynamic model was established and linearized according to the arbitrary initial angle of joints. After solving the analytical solutions of steady-state responses of the joints, the numerical solution was used to verify it. The results of theoretical analysis show that the two natural frequencies of the developed dynamic model are 2.9 Hz and 5.4 Hz, respectively, which meet the characteristic frequency range of pathological tremors. Then, combined with the measured parameters of human arm, a tremor simulation system was built, and the measured results of joint responses are in good agreement with the theoretical and simulation analysis results, which verifies the effectiveness of the theoretical model. The results show that the human arm pathological tremor simulation system designed in this paper can characterize the frequency and response amplitude of the human upper limb pathological tremor. Moreover, the relevant research lays a theoretical foundation and experimental conditions for the subsequent development of wearable tremor suppression devices.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-08-25
DOI
https://doi.org/10.7507/1001-5515.202412025
Primary Topic
Biomedical and Engineering Education
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Design and analysis of human arm pathological tremor simulation system].

Yu Jiang, Zhubing He, Haiping Liu, Qingsheng Liu et al.
PubMed
Biomedical and Engineering Education
article

[Design and analysis of human arm pathological tremor simulation system].

Yu Jiang, Zhubing He, Haiping Liu, Qingsheng Liu, Zhu Zhu
article en

Abstract

In order to characterize the characteristics of pathological tremor of human upper limb, a simulation system of pathological tremor of human arm was provided and its dynamic response was analyzed. Firstly, in this study, a two-degree-of-freedom human arm dynamic model was established and linearized according to the arbitrary initial angle of joints. After solving the analytical solutions of steady-state responses of the joints, the numerical solution was used to verify it. The results of theoretical analysis show that the two natural frequencies of the developed dynamic model are 2.9 Hz and 5.4 Hz, respectively, which meet the characteristic frequency range of pathological tremors. Then, combined with the measured parameters of human arm, a tremor simulation system was built, and the measured results of joint responses are in good agreement with the theoretical and simulation analysis results, which verifies the effectiveness of the theoretical model. The results show that the human arm pathological tremor simulation system designed in this paper can characterize the frequency and response amplitude of the human upper limb pathological tremor. Moreover, the relevant research lays a theoretical foundation and experimental conditions for the subsequent development of wearable tremor suppression devices.

PubMedVol. 42(4)
North University of China (CN), Peking University (CN), Peking University Third Hospital (CN), University of Science and Technology Beijing (CN)
Biomedical and Engineering Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[Design and analysis of human arm pathological tremor simulation system]. — Yu Jiang, Zhubing He, et al. · PubMed (2025) | TGRS Research Map | TGRS