Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements

An interferometer used for displacement measurement is typically adjusted to the center or another appropriate point of the interferometer fringe as a working point to yield maximum detection sensitivity and linearity. The interferometer is prone to varying misalignment in the course of measurements, most noticeable due to thermal drift affecting the interferometer dimensions. We introduce an automatic correction mechanism based on a proportional/integral (PI) control loop to remove any error in the alignment of the fiber interferometer, specifically long-term drift. The method is based on introducing a harmonic displacement by driving an optical element, which is a micro-cantilever in this work. The second harmonic of the interferometric signal that is shown to be present only for a misaligned Michelson or low-finesse Fabry-Pérot interferometer is processed using a lock-in detector, phase-locked to the drive signal, where the in-phase output signal is used as the feedback signal of the PI control loop operated with zero signal setpoint. The loop output control signal is amplified and supplied to the piezo element, adjusting the optical element to yield perfect alignment. As thermal drift is a slow process, the control loop can mostly be operated with a large time constant, allowing for a highly accurate stabilization, limiting misalignment to less than 2% of the interferometer fringe.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0269765
Citations
1
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements

K. Khachatryan, Michael Reichling, Alexander von Schmidsfeld
1 citations
Review of Scientific Instruments
Advanced Fiber Optic Sensors
0.73
article

Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements

K. Khachatryan, Michael Reichling, Alexander von Schmidsfeld
article en
1 citations

Abstract

An interferometer used for displacement measurement is typically adjusted to the center or another appropriate point of the interferometer fringe as a working point to yield maximum detection sensitivity and linearity. The interferometer is prone to varying misalignment in the course of measurements, most noticeable due to thermal drift affecting the interferometer dimensions. We introduce an automatic correction mechanism based on a proportional/integral (PI) control loop to remove any error in the alignment of the fiber interferometer, specifically long-term drift. The method is based on introducing a harmonic displacement by driving an optical element, which is a micro-cantilever in this work. The second harmonic of the interferometric signal that is shown to be present only for a misaligned Michelson or low-finesse Fabry-Pérot interferometer is processed using a lock-in detector, phase-locked to the drive signal, where the in-phase output signal is used as the feedback signal of the PI control loop operated with zero signal setpoint. The loop output control signal is amplified and supplied to the piezo element, adjusting the optical element to yield perfect alignment. As thermal drift is a slow process, the control loop can mostly be operated with a large time constant, allowing for a highly accurate stabilization, limiting misalignment to less than 2% of the interferometer fringe.

Review of Scientific InstrumentsVol. 96(9)
Osnabrück University (DE)
Openalex Percentile: Top 24%
Advanced Fiber Optic Sensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Highly accurate adjustment and stabilization of a fiber interferometer for displacement measurements — K. Khachatryan, Michael Reichling, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS