Sensitive broadband ultrasound sensor based on a low-loss high-Q fused-silica plano-concave microresonator

Optical ultrasound sensors can achieve high sensitivity, small element size, and broadband frequency response. Polymer plano-concave microresonators (PCMRs) are among the most sensitive ultrasound sensors, but achieving further increases in sensitivity is limited by the optical absorption of the polymer cavity material. To address this, the use of fused silica as the cavity material is investigated. We present findings supporting the assertion that the low compressibility of fused silica compared to polymeric materials can be overcome by exploiting its extremely low optical absorption to achieve high Q-factors approaching 10<sup>6</sup>. We also show that the high Q-factors can introduce laser phase noise unless very narrow linewidth (<150 Hz) laser sources are employed. In this work, a fused silica PCMR ultrasound sensor is reported that has an NEP of 0.7 mPa/√Hz, a broadband frequency response with a -3 dB bandwidth of 2.5 MHz, and low directional sensitivity.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-09-03
DOI
https://doi.org/10.1364/oe.572433
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive broadband ultrasound sensor based on a low-loss high-Q fused-silica plano-concave microresonator

David Martín-Sánchez, Paul C. Beard, Edward Zhang, James A. Guggenheim et al.
5 links
Optics Express
Photoacoustic and Ultrasonic Imaging
article

Sensitive broadband ultrasound sensor based on a low-loss high-Q fused-silica plano-concave microresonator

David Martín-Sánchez, Paul C. Beard, Edward Zhang, James A. Guggenheim, Zhixin Liu
article en

Abstract

Optical ultrasound sensors can achieve high sensitivity, small element size, and broadband frequency response. Polymer plano-concave microresonators (PCMRs) are among the most sensitive ultrasound sensors, but achieving further increases in sensitivity is limited by the optical absorption of the polymer cavity material. To address this, the use of fused silica as the cavity material is investigated. We present findings supporting the assertion that the low compressibility of fused silica compared to polymeric materials can be overcome by exploiting its extremely low optical absorption to achieve high Q-factors approaching 10<sup>6</sup>. We also show that the high Q-factors can introduce laser phase noise unless very narrow linewidth (<150 Hz) laser sources are employed. In this work, a fused silica PCMR ultrasound sensor is reported that has an NEP of 0.7 mPa/√Hz, a broadband frequency response with a -3 dB bandwidth of 2.5 MHz, and low directional sensitivity.

Optics ExpressVol. 33(19)
Instituto de Microelectrónica de Sevilla (ES), Universidad de Sevilla (ES), University of Birmingham (GB)
Openalex Percentile: Top 78%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.