Clozapine Toxicity Following Aortic Valve Replacement in the Context of Pleural Effusion: A Case Report

Clozapine toxicity is a potentially life-threatening condition that can result from altered drug metabolism, leading to elevated serum levels and systemic adverse effects. Although it is commonly associated with infections and metabolic changes, its occurrence in the setting of recent cardiac surgery and pleural effusion is not well documented. We present the case of a 42-year-old female with a history of schizoaffective disorder, bipolar disorder, and recent mechanical aortic valve replacement, who developed worsening dyspnea and postoperative pleural effusions. Her hospital course was complicated by supratherapeutic clozapine levels, recurrent pleural effusions requiring thoracentesis and chest tube placement, and anticoagulation management challenges due to the mechanical valve. Despite diuresis and pleural drainage, her symptoms persisted, leading to clozapine discontinuation. After dose adjustments and close monitoring, her respiratory status improved, and serum clozapine levels returned to normal.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-03
DOI
https://doi.org/10.7759/cureus.91545
Primary Topic
Schizophrenia research and treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clozapine Toxicity Following Aortic Valve Replacement in the Context of Pleural Effusion: A Case Report

Akoi Bore Joseph, Naima T. Joseph, D. Joseph
Cureus
Schizophrenia research and treatment
article

Clozapine Toxicity Following Aortic Valve Replacement in the Context of Pleural Effusion: A Case Report

Akoi Bore Joseph, Naima T. Joseph, D. Joseph
article en

Abstract

Clozapine toxicity is a potentially life-threatening condition that can result from altered drug metabolism, leading to elevated serum levels and systemic adverse effects. Although it is commonly associated with infections and metabolic changes, its occurrence in the setting of recent cardiac surgery and pleural effusion is not well documented. We present the case of a 42-year-old female with a history of schizoaffective disorder, bipolar disorder, and recent mechanical aortic valve replacement, who developed worsening dyspnea and postoperative pleural effusions. Her hospital course was complicated by supratherapeutic clozapine levels, recurrent pleural effusions requiring thoracentesis and chest tube placement, and anticoagulation management challenges due to the mechanical valve. Despite diuresis and pleural drainage, her symptoms persisted, leading to clozapine discontinuation. After dose adjustments and close monitoring, her respiratory status improved, and serum clozapine levels returned to normal.

CureusVol. 17(9)
Albany Medical Center Hospital (US)
Openalex Percentile: Top 73%
Schizophrenia research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clozapine Toxicity Following Aortic Valve Replacement in the Context of Pleural Effusion: A Case Report — Akoi Bore Joseph, Naima T. Joseph, et al. · Cureus (2025) | TGRS Research Map | TGRS