On-chip electrochemical detection of dissolved oxygen: Eliminating the requirement for a permeable selective membrane

Membrane-free electrochemical dissolved oxygen sensors were developed using micro interdigitated electrode arrays. The optimised sensor for detection of dissolved oxygen should contain a gold generator electrode to produce hydrogen peroxide, and a platinum collector electrode for the subsequent detection. The microfabrication process required platinum electrodeposition onto one comb of a gold interdigitated array. The deposition also decreased the inter-electrode gap and increased the collection efficiency. The dual metal IDE was then used to sense dissolved oxygen in water. A pre-treatment step was also required to improve the sensitivity of platinum to hydrogen peroxide ensuring a clean, reproducible surface for each test. The developed sensor accurately detected oxygen concentrations between 0 and 9 ppm, with a sensitivity of 1.59 nA/ppm and an LOD of 0.36 ppm. The detection of oxygen was also tested in the presence of unknown interferents, in estuarine river water, and with known interferents. It was found that the magnitude of hydrogen peroxide oxidation was generally unaffected by the presence of interferents, indicating a potential for interferent free oxygen detection without the requirement of oxygen permeable membranes. • Micro interdigitated electrode arrays enable membrane-free dissolved oxygen sensors. • Dual IDEs used gold to produce peroxide detected at a plated platinum collector. • Hydrogen peroxide oxidation is unaffected by the presence of interferents.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-09-03
DOI
https://doi.org/10.1016/j.snb.2025.138689
Citations
3
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-chip electrochemical detection of dissolved oxygen: Eliminating the requirement for a permeable selective membrane

James F. Rohan, Alan O’Riordan, Fiona Barry, Ian Seymour
3 citations
Sensors and Actuators B Chemical
Electrochemical Analysis and Applications
1.55
article

On-chip electrochemical detection of dissolved oxygen: Eliminating the requirement for a permeable selective membrane

James F. Rohan, Alan O’Riordan, Fiona Barry, Ian Seymour
article en
3 citations

Abstract

Membrane-free electrochemical dissolved oxygen sensors were developed using micro interdigitated electrode arrays. The optimised sensor for detection of dissolved oxygen should contain a gold generator electrode to produce hydrogen peroxide, and a platinum collector electrode for the subsequent detection. The microfabrication process required platinum electrodeposition onto one comb of a gold interdigitated array. The deposition also decreased the inter-electrode gap and increased the collection efficiency. The dual metal IDE was then used to sense dissolved oxygen in water. A pre-treatment step was also required to improve the sensitivity of platinum to hydrogen peroxide ensuring a clean, reproducible surface for each test. The developed sensor accurately detected oxygen concentrations between 0 and 9 ppm, with a sensitivity of 1.59 nA/ppm and an LOD of 0.36 ppm. The detection of oxygen was also tested in the presence of unknown interferents, in estuarine river water, and with known interferents. It was found that the magnitude of hydrogen peroxide oxidation was generally unaffected by the presence of interferents, indicating a potential for interferent free oxygen detection without the requirement of oxygen permeable membranes. • Micro interdigitated electrode arrays enable membrane-free dissolved oxygen sensors. • Dual IDEs used gold to produce peroxide detected at a plated platinum collector. • Hydrogen peroxide oxidation is unaffected by the presence of interferents.

Sensors and Actuators B ChemicalVol. 446
University College Cork (IE)
Openalex Percentile: Top 17%
Electrochemical Analysis and Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-chip electrochemical detection of dissolved oxygen: Eliminating the requirement for a permeable selective membrane — James F. Rohan, Alan O’Riordan, et al. · Sensors and Actuators B Chemical (2025) | TGRS Research Map | TGRS