Stroke-Aware CycleGAN: Improving Low-Field MRI Image Quality for Accurate Stroke Assessment

Low-field portable magnetic resonance imaging (pMRI) devices address a crucial requirement in the realm of healthcare by offering the capability for on-demand and timely access to MRI, especially in the context of routine stroke emergency. Nevertheless, images acquired by these devices often exhibit poor clarity and low resolution, resulting in their reduced potential to support precise diagnostic evaluations and lesion quantification. In this paper, we propose a 3D deep learning based model, named Stroke-Aware CycleGAN (SA-CycleGAN), to enhance the quality of low-field images for further improving diagnosis of routine stroke. Firstly, based on traditional CycleGAN, SA-CycleGAN incorporates a prior of stroke lesions by applying a novel spatial feature transform mechanism. Secondly, gradient difference losses are combined to deal with the problem that the synthesized images tend to be overly smooth. We present a dataset comprising 101 paired high-field and low-field diffusion-weighted imaging (DWI), which were acquired through dual scans of the same patient in close temporal proximity. Our experiments demonstrate that SA-CycleGAN is capable of generating images with higher quality and greater clarity compared to the original low-field DWI. Additionally, in terms of quantifying stroke lesions, SA-CycleGAN outperforms existing methods. The lesion volume exhibits a strong correlation between the generated images and the high-field images, with R=0.852. In contrast, the lesion volume correlation between the low-field images and the high-field images is notably lower, with R=0.462. Furthermore, the mean absolute difference in lesion volumes between the generated images and high-field images ( $1.73\pm 2.03$ mL) was significantly smaller than the difference between the low-field images and high-field images ( $2.53\pm 4.24$ mL). It shows that the synthesized images not only exhibit superior visual clarity compared to the low-field acquired images, but also possess a high degree of consistency with high-field images. In routine clinical practice, the proposed SA-CycleGAN offers an accessible and cost-effective means of rapidly obtaining higher-quality images, holding the potential to enhance the efficiency and accuracy of stroke diagnosis in routine clinical settings. The code and trained models will be released on GitHub: SA-CycleGAN.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-09-03
DOI
https://doi.org/10.1109/tmi.2025.3605566
Citations
1
Primary Topic
Brain Tumor Detection and Classification
Type
article
Field-Weighted Citation Impact
0.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stroke-Aware CycleGAN: Improving Low-Field MRI Image Quality for Accurate Stroke Assessment

Jian Cheng, Hao Li, Yu Zhou, Xuewei Xie et al.
1 citations
IEEE Transactions on Medical Imaging
Brain Tumor Detection and Classification
0.84
article

Stroke-Aware CycleGAN: Improving Low-Field MRI Image Quality for Accurate Stroke Assessment

Jian Cheng, Hao Li, Yu Zhou, Xuewei Xie, Yue Suo, Xia Meng, Tao Liu, Ning Wang, Yongjun Wang, Zhe Zhang, Ziyang Liu, Jing Jing, Chunguang Zhang, Bingshan Xue, Wanlin Zhu, Yihuai Wang
article en
1 citations

Abstract

Low-field portable magnetic resonance imaging (pMRI) devices address a crucial requirement in the realm of healthcare by offering the capability for on-demand and timely access to MRI, especially in the context of routine stroke emergency. Nevertheless, images acquired by these devices often exhibit poor clarity and low resolution, resulting in their reduced potential to support precise diagnostic evaluations and lesion quantification. In this paper, we propose a 3D deep learning based model, named Stroke-Aware CycleGAN (SA-CycleGAN), to enhance the quality of low-field images for further improving diagnosis of routine stroke. Firstly, based on traditional CycleGAN, SA-CycleGAN incorporates a prior of stroke lesions by applying a novel spatial feature transform mechanism. Secondly, gradient difference losses are combined to deal with the problem that the synthesized images tend to be overly smooth. We present a dataset comprising 101 paired high-field and low-field diffusion-weighted imaging (DWI), which were acquired through dual scans of the same patient in close temporal proximity. Our experiments demonstrate that SA-CycleGAN is capable of generating images with higher quality and greater clarity compared to the original low-field DWI. Additionally, in terms of quantifying stroke lesions, SA-CycleGAN outperforms existing methods. The lesion volume exhibits a strong correlation between the generated images and the high-field images, with R=0.852. In contrast, the lesion volume correlation between the low-field images and the high-field images is notably lower, with R=0.462. Furthermore, the mean absolute difference in lesion volumes between the generated images and high-field images ( $1.73\pm 2.03$ mL) was significantly smaller than the difference between the low-field images and high-field images ( $2.53\pm 4.24$ mL). It shows that the synthesized images not only exhibit superior visual clarity compared to the low-field acquired images, but also possess a high degree of consistency with high-field images. In routine clinical practice, the proposed SA-CycleGAN offers an accessible and cost-effective means of rapidly obtaining higher-quality images, holding the potential to enhance the efficiency and accuracy of stroke diagnosis in routine clinical settings. The code and trained models will be released on GitHub: SA-CycleGAN.

IEEE Transactions on Medical ImagingVol. 45(2)
Capital Medical University (CN), Beijing VDJBio (China) (CN), Beijing Tian Tan Hospital (CN), National Clinical Research Center for Digestive Diseases (CN), Beijing Founder Electronics (China) (CN), Shenwu Technology Group Corp (China) (CN), OriginWater (China) (CN), Beihang University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 22%
Brain Tumor Detection and Classification
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.