Can low-cost sensors (LCS) enhance air quality monitoring for personal pollution exposure assessment?

Abstract Laboratory and field assessments of low-cost sensors (LCS) are essential for ensuring the accuracy of PM 2.5 measurements collected by citizens in air quality campaigns. Evaluation of Sensirion SPS30 (LCS SPS30) in controlled laboratory setting showed a coefficient of determination ( R 2 ) ranging from 0.81–0.99 and a root mean square error (RMSE) from 0.81–61.72 μg m −3 , at average concentration of 21.5 μg m −3 . In contrast, co-location assessment at an average concentration of 9 μg m −3 resulted in R 2 of 0.5 and a RMSE of 6.82 μg m −3 . The results demonstrated that the sensor met micro-environmental monitoring standards (accuracy < 25%) and United States Environmental Protection Agency's performance criteria (RMSE ≤ 7 μg m −3 , R 2 > 0.7) only at relative humidity (RH) levels below 60%, emphasising its strong sensitivity to RH and the need for RH-dependent data corrections. The observed underestimation or overestimation of PM 2.5 readings was primarily attributed to variations in particle composition and concentration. Despite accuracy variations, LCSs can effectively capture spatiotemporal urban air quality patterns and identify pollution hotspots in community monitoring, particularly in low-pollution environments. In a citizen-led PM 2.5 monitoring campaign in Maribor, Slovenia, the lowest concentrations were recorded at 15:00 (2.9 μg m −3 ), while the highest occurred during the morning rush-hour (4.8 μg m −3 ), likely attributed to the planetary boundary layer’s impact on atmospheric particulate dispersion. Spatial analysis revealed that hotspots clustered near intersections, where vehicle waiting time is the longest.

Authors

Institutions

Publication Details

Journal
Environmental Research Communications
Published
2025-09-01
DOI
https://doi.org/10.1088/2515-7620/ae02ef
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can low-cost sensors (LCS) enhance air quality monitoring for personal pollution exposure assessment?

Alenka Mauko Pranjić, Radmila Milačić, Janez Ščančar, Anja Ilenič et al.
1 links
Environmental Research Communications
Air Quality Monitoring and Forecasting
article

Can low-cost sensors (LCS) enhance air quality monitoring for personal pollution exposure assessment?

Alenka Mauko Pranjić, Radmila Milačić, Janez Ščančar, Anja Ilenič, Prashant Kumar
article en

Abstract

Abstract Laboratory and field assessments of low-cost sensors (LCS) are essential for ensuring the accuracy of PM 2.5 measurements collected by citizens in air quality campaigns. Evaluation of Sensirion SPS30 (LCS SPS30) in controlled laboratory setting showed a coefficient of determination ( R 2 ) ranging from 0.81–0.99 and a root mean square error (RMSE) from 0.81–61.72 μg m −3 , at average concentration of 21.5 μg m −3 . In contrast, co-location assessment at an average concentration of 9 μg m −3 resulted in R 2 of 0.5 and a RMSE of 6.82 μg m −3 . The results demonstrated that the sensor met micro-environmental monitoring standards (accuracy < 25%) and United States Environmental Protection Agency's performance criteria (RMSE ≤ 7 μg m −3 , R 2 > 0.7) only at relative humidity (RH) levels below 60%, emphasising its strong sensitivity to RH and the need for RH-dependent data corrections. The observed underestimation or overestimation of PM 2.5 readings was primarily attributed to variations in particle composition and concentration. Despite accuracy variations, LCSs can effectively capture spatiotemporal urban air quality patterns and identify pollution hotspots in community monitoring, particularly in low-pollution environments. In a citizen-led PM 2.5 monitoring campaign in Maribor, Slovenia, the lowest concentrations were recorded at 15:00 (2.9 μg m −3 ), while the highest occurred during the morning rush-hour (4.8 μg m −3 ), likely attributed to the planetary boundary layer’s impact on atmospheric particulate dispersion. Spatial analysis revealed that hotspots clustered near intersections, where vehicle waiting time is the longest.

Environmental Research CommunicationsVol. 7(9)
University of Surrey (GB), Jožef Stefan Institute (SI), Jožef Stefan International Postgraduate School (SI), Slovenian National Building and Civil Engineering Institute (SI), Institute for Sustainability (GB)
Javna Agencija za Raziskovalno Dejavnost RS, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 79%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.