Comprehensive design study of the Si/TlBr semiconductor-based Compton camera for 478 keV prompt gamma-ray imaging in boron neutron capture therapy

Abstract Boron neutron capture therapy (BNCT) can selectively destroy tumor cells while minimizing damage to normal tissue through boron neutron capture reactions. Real-time determination and localization of the in vivo boron dose during treatment is a critical challenge in BNCT. A promising solution involves imaging the 478 keV prompt gamma rays emitted from these capture reactions. This study presents a comprehensive simulation-based design of a Si/TlBr semiconductor Compton camera system for 478 keV prompt gamma-ray imaging in clinical BNCT. The design process includes optimization of detector geometry using isotropic, monoenergetic 478 keV gamma-ray sources; development of neutron and photon shielding under therapeutic neutron beam irradiation of a head phantom; and evaluation of imaging performance under clinically relevant conditions with low in vivo 10 B concentrations. The results provide valuable insights to support the further development of Compton camera systems for BNCT applications.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-09-01
DOI
https://doi.org/10.35848/1347-4065/ae02d5
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive design study of the Si/TlBr semiconductor-based Compton camera for 478 keV prompt gamma-ray imaging in boron neutron capture therapy

Makoto Sakai, Isao Murata, Nikolaos Voulgaris, Sachie Kusaka et al.
1 links
Japanese Journal of Applied Physics
Nuclear Physics and Applications
article

Comprehensive design study of the Si/TlBr semiconductor-based Compton camera for 478 keV prompt gamma-ray imaging in boron neutron capture therapy

Makoto Sakai, Isao Murata, Nikolaos Voulgaris, Sachie Kusaka, Shingo Tamaki, Jiye Qiu
article en

Abstract

Abstract Boron neutron capture therapy (BNCT) can selectively destroy tumor cells while minimizing damage to normal tissue through boron neutron capture reactions. Real-time determination and localization of the in vivo boron dose during treatment is a critical challenge in BNCT. A promising solution involves imaging the 478 keV prompt gamma rays emitted from these capture reactions. This study presents a comprehensive simulation-based design of a Si/TlBr semiconductor Compton camera system for 478 keV prompt gamma-ray imaging in clinical BNCT. The design process includes optimization of detector geometry using isotropic, monoenergetic 478 keV gamma-ray sources; development of neutron and photon shielding under therapeutic neutron beam irradiation of a head phantom; and evaluation of imaging performance under clinically relevant conditions with low in vivo 10 B concentrations. The results provide valuable insights to support the further development of Compton camera systems for BNCT applications.

Japanese Journal of Applied PhysicsVol. 64(9)
Osaka Gakuin University (JP), Kyushu University (JP), The University of Osaka (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 70%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comprehensive design study of the Si/TlBr semiconductor-based Compton camera for 478 keV prompt gamma-ray imaging in boron neutron capture therapy — Makoto Sakai, Isao Murata, et al. · Japanese Journal of Applied Physics (2025) | TGRS Research Map | TGRS