Vendor and software based variation in left atrial strain measurements: implications for clinical practice

Left atrial strain (LAS) is a valuable echocardiographic marker of left atrial function with growing clinical utility. However, variability in LAS measurements across software vendors remains a barrier to its routine clinical use. This study aimed to compare LAS measurements obtained using a dedicated left atrial-specific measurement tool (AFI-LA (General Electric (GE)) with those derived from established LV-based strain platforms: GE EchoPAC (mid-myocardial and endocardial tracking) and TomTec-Arena (feature tracking), used for measurement of LAS. LAS was measured in 112 subjects (72 individuals in sinus rhythm and 40 paroxysmal atrial fibrillation (PAF) patients in sinus rhythm at the time of transthoracic echocardiography). Reservoir (ƐR), contractile (ƐCT), and conduit (ƐCD) phasic strain were measured using AFI-LA and compared with GE-mid, GE-endo, and TomTec strain measurements. Agreement was assessed using Bland-Altman analysis and Pearson correlation. Inter- and intra-observer reproducibility was evaluated. AFI-LA measurements showed good correlation with both platforms (r ≥ 0.7, p < 0.001). AFI-LA consistently underestimated strain values across all phases compared to GE-mid, GE-endo, and TomTec, with the smallest bias observed against GE-mid. Proportional bias was present, particularly at higher strain values. Inter- and intra-observer reproducibility of AFI-LA measurements was high (r > 0.85). AFI-LA provides LAS measurements that are most comparable to GE mid-myocardial strain but demonstrates systematic underestimation compared to GE endocardial and TomTec-derived values. These differences underscore the need for vendor-specific calibration before AFI-LA can be used for serial assessments or applied using existing clinical threshold values. Larger validation studies are needed to support standardization and broader clinical adoption.

Authors

Institutions

Publication Details

Journal
The International Journal of Cardiovascular Imaging
Published
2025-09-03
DOI
https://doi.org/10.1007/s10554-025-03499-3
Citations
1
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vendor and software based variation in left atrial strain measurements: implications for clinical practice

Faraz Pathan, Aaisha Ferkh, Liza Thomas, O. Archer et al.
1 citations
The International Journal of Cardiovascular Imaging
Cardiovascular Function and Risk Factors
1.39
article

Vendor and software based variation in left atrial strain measurements: implications for clinical practice

Faraz Pathan, Aaisha Ferkh, Liza Thomas, O. Archer, Vlad Danaila, P. Brown, L. Stefani, S K Khanna
article en
1 citations

Abstract

Left atrial strain (LAS) is a valuable echocardiographic marker of left atrial function with growing clinical utility. However, variability in LAS measurements across software vendors remains a barrier to its routine clinical use. This study aimed to compare LAS measurements obtained using a dedicated left atrial-specific measurement tool (AFI-LA (General Electric (GE)) with those derived from established LV-based strain platforms: GE EchoPAC (mid-myocardial and endocardial tracking) and TomTec-Arena (feature tracking), used for measurement of LAS. LAS was measured in 112 subjects (72 individuals in sinus rhythm and 40 paroxysmal atrial fibrillation (PAF) patients in sinus rhythm at the time of transthoracic echocardiography). Reservoir (ƐR), contractile (ƐCT), and conduit (ƐCD) phasic strain were measured using AFI-LA and compared with GE-mid, GE-endo, and TomTec strain measurements. Agreement was assessed using Bland-Altman analysis and Pearson correlation. Inter- and intra-observer reproducibility was evaluated. AFI-LA measurements showed good correlation with both platforms (r ≥ 0.7, p < 0.001). AFI-LA consistently underestimated strain values across all phases compared to GE-mid, GE-endo, and TomTec, with the smallest bias observed against GE-mid. Proportional bias was present, particularly at higher strain values. Inter- and intra-observer reproducibility of AFI-LA measurements was high (r > 0.85). AFI-LA provides LAS measurements that are most comparable to GE mid-myocardial strain but demonstrates systematic underestimation compared to GE endocardial and TomTec-derived values. These differences underscore the need for vendor-specific calibration before AFI-LA can be used for serial assessments or applied using existing clinical threshold values. Larger validation studies are needed to support standardization and broader clinical adoption.

The International Journal of Cardiovascular ImagingVol. 41(10)
The University of Sydney (AU), Epworth Hospital (AU), Nepean Hospital (AU), UNSW Sydney (AU), Sydney Local Health District (AU)
University of Sydney
Openalex Percentile: Top 15%
Cardiovascular Function and Risk Factors
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.