Clinical utility of semi–automated EEG electric source imaging of interictal discharges in presurgical evaluation and surgical treatment decision making

Purpose We aimed to evaluate the clinical utility of the semi-automated EEG source imaging (ESI) analysis results during presurgical workup in epilepsy surgery candidates. Methods Forty consecutive presurgical patients with focal epilepsy, evaluated during 2021–2022, with a mean age of 35.0 years (range, 2–59), were included. The long-term video-EEG recordings were analyzed using Epilog PreOp (Clouds of Care, Ghent, Belgium). Automatically detected spike clusters were evaluated, and source localization at the half-rising phase of the averaged spike peak was used for ESI localization at the lobar level. The evaluation by the multidisciplinary epilepsy surgery team (MDT), including clinical and multimodal presurgical evaluation data, was used to assess the clinical utility of ESI results in the decision-making process. Results Twenty of 40 patients were classified as non-lesional based on magnetic resonance imaging (MRI), and 22 of 36 had focal PET hypometabolism. In automated ESI analyses, no epileptic spikes were detected in four patients (10%). The largest spike clusters were localized to the temporal (58%), frontal (23%), and occipital lobes (3%) or the insula (8%). ESI results had an impact on the suggested treatment choice in 45% of cases and did not significantly affect clinical decision-making in 35% of cases. In patients who underwent resective surgery or had MRI lesions in the temporal lobe, ESI findings were more likely to be consistent with other findings and to complement clinical decisions (Pearson chi-square p = 0.016 and 0.027). Conclusion This study demonstrates that commercial automated spike detection analyses and source localization, when reviewed by an experienced MDT, can aid clinical decision-making in about 40% of patients, especially for patients in whom resective epilepsy surgery is a feasible option.

Authors

Institutions

Publication Details

Journal
Frontiers in Neurology
Published
2025-09-03
DOI
https://doi.org/10.3389/fneur.2025.1598265
Primary Topic
Epilepsy research and treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical utility of semi–automated EEG electric source imaging of interictal discharges in presurgical evaluation and surgical treatment decision making

Reetta Kälviäinen, Päivi Koskenkorva, Leena Jutila, Jelena Hyppönen et al.
1 links
Frontiers in Neurology
Epilepsy research and treatment
article

Clinical utility of semi–automated EEG electric source imaging of interictal discharges in presurgical evaluation and surgical treatment decision making

Reetta Kälviäinen, Päivi Koskenkorva, Leena Jutila, Jelena Hyppönen, Anni Saarela, Esa Mervaala, Henri Eronen
article en

Abstract

Purpose We aimed to evaluate the clinical utility of the semi-automated EEG source imaging (ESI) analysis results during presurgical workup in epilepsy surgery candidates. Methods Forty consecutive presurgical patients with focal epilepsy, evaluated during 2021–2022, with a mean age of 35.0 years (range, 2–59), were included. The long-term video-EEG recordings were analyzed using Epilog PreOp (Clouds of Care, Ghent, Belgium). Automatically detected spike clusters were evaluated, and source localization at the half-rising phase of the averaged spike peak was used for ESI localization at the lobar level. The evaluation by the multidisciplinary epilepsy surgery team (MDT), including clinical and multimodal presurgical evaluation data, was used to assess the clinical utility of ESI results in the decision-making process. Results Twenty of 40 patients were classified as non-lesional based on magnetic resonance imaging (MRI), and 22 of 36 had focal PET hypometabolism. In automated ESI analyses, no epileptic spikes were detected in four patients (10%). The largest spike clusters were localized to the temporal (58%), frontal (23%), and occipital lobes (3%) or the insula (8%). ESI results had an impact on the suggested treatment choice in 45% of cases and did not significantly affect clinical decision-making in 35% of cases. In patients who underwent resective surgery or had MRI lesions in the temporal lobe, ESI findings were more likely to be consistent with other findings and to complement clinical decisions (Pearson chi-square p = 0.016 and 0.027). Conclusion This study demonstrates that commercial automated spike detection analyses and source localization, when reviewed by an experienced MDT, can aid clinical decision-making in about 40% of patients, especially for patients in whom resective epilepsy surgery is a feasible option.

Frontiers in NeurologyVol. 16
University of Eastern Finland (FI), Kuopio University Hospital (FI)
Kuopion Yliopistollinen Sairaala
Openalex Percentile: Top 73%
Epilepsy research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.