Islanding detection of integrated DG system using rate of change of frequency over reactive power

This paper offers a passive islanding detection method that is effective for distributed generation. When a distributed generator (DG) keeps a location powered even when access to the external electrical grid is lost, this circumstance is referred to as islanding. The power distribution system currently includes distributed generators (DGs), which provide inexpensive electricity and have fewer environmental impacts. Sometimes, these DGs continue to supply the nearby loads because of line outages and islands made by system separations. As a result, there are scenarios with unacceptable power quality. The islanding is identified if the result of the rate of change of frequency over reactive power exceeds the threshold value. The MATLAB test results from this study demonstrate the effectiveness of the suggested approach for different islanding and non-islanding scenarios.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Published
2025-09-01
DOI
https://doi.org/10.11591/ijpeds.v16.i3.pp1637-1644
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Islanding detection of integrated DG system using rate of change of frequency over reactive power

Giriprasad Ambati, Ch. Rami Reddy, B. Venkata Seshu Kumari, S. Sai Srilakshmi et al.
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Islanding Detection in Power Systems
article

Islanding detection of integrated DG system using rate of change of frequency over reactive power

Giriprasad Ambati, Ch. Rami Reddy, B. Venkata Seshu Kumari, S. Sai Srilakshmi, Karri Sairamakrishna Buchireddy
article en

Abstract

This paper offers a passive islanding detection method that is effective for distributed generation. When a distributed generator (DG) keeps a location powered even when access to the external electrical grid is lost, this circumstance is referred to as islanding. The power distribution system currently includes distributed generators (DGs), which provide inexpensive electricity and have fewer environmental impacts. Sometimes, these DGs continue to supply the nearby loads because of line outages and islands made by system separations. As a result, there are scenarios with unacceptable power quality. The islanding is identified if the result of the rate of change of frequency over reactive power exceeds the threshold value. The MATLAB test results from this study demonstrate the effectiveness of the suggested approach for different islanding and non-islanding scenarios.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer EngineeringVol. 16(3)
Elgin Community College (US), Applied Science Private University (JO), R2M Solution (Italy) (IT), Institute of Engineering (NP)
Openalex Percentile: Top 78%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.