Effectiveness of the Stage 4 Smart Insulin Pen DIA:CONN P8 for Glycemic Control in a Real-World Setting
This study evaluated whether a stage 4 smart insulin pen (SIP) provides superior glycemic control compared with a traditional insulin pen (TIP) in individuals with intensively insulin-treated diabetes. Forty-two adults with continuous glucose monitoring (CGM), multiple daily insulin injections, and no prior SIP use were included. After diabetes self-management education (DSME), the SIP group (n=21) initiated SIP, whereas the TIP group (n=21) continued their usual regimens. Glycemic metrics were assessed using CGM before and 2 weeks after DSME. Both groups demonstrated significant improvements in glycemic outcomes. However, SIP users exhibited superior improvements in the percentage of time in range, percentage of time below range (%TBR) <70 mg/dL, %TBR <54 mg/dL, and glycemic risk index compared with TIP users (between-group difference [BD] 11.0%, P=0.046; BD -2.6%, P=0.024; BD -0.9%, P=0.027; BD -18.2, P=0.022, respectively). These findings suggest that SIP, with its bolus calculation and CGM integration, is associated with improved glycemic outcomes in adults with intensively insulin-treated diabetes.
Authors
- So Yoon Kwon (ORCID: https://orcid.org/0000-0002-6282-6612)
- Hojoong Kwak (ORCID: https://orcid.org/0000-0003-3932-8946)
- Jae Hyeon Kim (ORCID: https://orcid.org/0000-0001-5001-963X)
Institutions
- Samsung Medical Center (KR)
- Daegu Catholic University Medical Center (KR)
- Sungkyunkwan University (KR)
Publication Details
- Journal
- Diabetes & Metabolism Journal
- Published
- 2025-09-03
- DOI
- https://doi.org/10.4093/dmj.2025.0112
- Primary Topic
- Diabetes Management and Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00