A128 The dual-layer cguard stent is safe and effective in emergent carotid artery stenting and in tandem occlusions: a multi-centric study

<h3>Introduction</h3> Dual-layer stents have fallen into disrepute after several studies reported high rates of in-stent occlusions in acute stroke treatments. The CGuard stent is a new-generation hybrid dual-layer stent that has been designed to provide less thrombogenicity and to prevent peri- and postinterventional emboli. <h3>Aim of Study</h3> The aim of the study is to evaluate the safety and efficacy of the CGuard stent for the acute treatment of occlusion or high-grade stenosis of the extracranial internal carotid artery (ICA) in patients with acute ischemic stroke (AIS) with and without concomitant intracranial large vessel occlusion (LVO). <h3>Method</h3> All patients who underwent emergent carotid artery stenting (CAS) with the CGuard stent were identified and analyzed from the stroke registries from four tertiary German stroke centers. Clinical, procedural, and imaging data were evaluated. Stent patency within 72 h, intracranial hemorrhage, and modified Rankin score (mRS) at discharge were the safety and efficacy end points. <h3>Results</h3> Overall, ninety-six patients were included (mean age 70.2 ± 11.8, 66 males (68.8%), median NIHSS score at admission 11 (7–17), IV lysis: n = 44 (45.8%)). Stent placement was successful in all patients. Eighty-three (86.4%) patients had tandem occlusions. In-stent occlusion occurred in 5 patients (5.2%) and 3 patients developed early in-stent stenosis (3.1%). Median mRS at discharge was 2 (1–4). <h3>Conclusion</h3> In this multicenter study, the use of the dual-layer CGuard stent for emergent CAS, particularly in tandem occlusions, was safe and resulted in low rates of in-stent occlusions. <h3>Conflict of Interest</h3> No

Authors

Institutions

Publication Details

Published
2025-09-01
DOI
https://doi.org/10.1136/jnis-2025-esmint.168
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A128 The dual-layer cguard stent is safe and effective in emergent carotid artery stenting and in tandem occlusions: a multi-centric study

Franziska Dorn, Marcel Wolf, Mousa Zidan, Christian Gronemann et al.
Cerebrovascular and Carotid Artery Diseases
article

A128 The dual-layer cguard stent is safe and effective in emergent carotid artery stenting and in tandem occlusions: a multi-centric study

Franziska Dorn, Marcel Wolf, Mousa Zidan, Christian Gronemann, Nils Lehnen, Hannes Nordmeyer, Carolin Brockmann, Keil Fee Christiane, Daniel Paech, Yves Leonard Voss
article en

Abstract

<h3>Introduction</h3> Dual-layer stents have fallen into disrepute after several studies reported high rates of in-stent occlusions in acute stroke treatments. The CGuard stent is a new-generation hybrid dual-layer stent that has been designed to provide less thrombogenicity and to prevent peri- and postinterventional emboli. <h3>Aim of Study</h3> The aim of the study is to evaluate the safety and efficacy of the CGuard stent for the acute treatment of occlusion or high-grade stenosis of the extracranial internal carotid artery (ICA) in patients with acute ischemic stroke (AIS) with and without concomitant intracranial large vessel occlusion (LVO). <h3>Method</h3> All patients who underwent emergent carotid artery stenting (CAS) with the CGuard stent were identified and analyzed from the stroke registries from four tertiary German stroke centers. Clinical, procedural, and imaging data were evaluated. Stent patency within 72 h, intracranial hemorrhage, and modified Rankin score (mRS) at discharge were the safety and efficacy end points. <h3>Results</h3> Overall, ninety-six patients were included (mean age 70.2 ± 11.8, 66 males (68.8%), median NIHSS score at admission 11 (7–17), IV lysis: n = 44 (45.8%)). Stent placement was successful in all patients. Eighty-three (86.4%) patients had tandem occlusions. In-stent occlusion occurred in 5 patients (5.2%) and 3 patients developed early in-stent stenosis (3.1%). Median mRS at discharge was 2 (1–4). <h3>Conclusion</h3> In this multicenter study, the use of the dual-layer CGuard stent for emergent CAS, particularly in tandem occlusions, was safe and resulted in low rates of in-stent occlusions. <h3>Conflict of Interest</h3> No

Goethe University Frankfurt (DE), University of Applied Sciences Mainz (DE), Johannes Gutenberg University Mainz (DE), University Hospital Bonn (DE), University Hospital Frankfurt (DE), Energiewerke Nord (Germany) (DE)
Openalex Percentile: Top 66%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.