C74 Inedit (iVascular) distal balloon guide catheter overcomes tortuous and looped carotid artery during mechanical thrombectomy

<h3>Introduction</h3> Carotid artery tortuosity is a challange in the endovascular treatment of ischemic stroke patients, leading to technical failure in mechanical thrombectomy and potentialy worse outcome. Distal balloon guide catheters may overcome this obstacles <h3>Case Description</h3> An 83 y old woman suffered an acute ischemic stroke caused by an occlusion of the proximal M1 segment of the right middle cerebral artery. High ASPECT score and a favourable CT perfusion made her a good candidate for mechanical thrombectomy. However CT angiography demonstrated a type 3 aortic arch, a very tortuous common carotid artery and a looping (coiling) in the cervical segment of the right internal carotid artery. Through an 8 F long sheath in the brachiocephalic trunc, a 6 F distal balloon guide catheter (iNedit, iVascular) easily passed the carotid artery tortuosity (CAT) and looping in the internal carotid artery upon the cavernosal part of the carotid artery Succesfull mechanical thrombectomy with stentretriever under distal ballon occlusion was performed. <h3>Final angiographic result</h3> TICI 3 in one pass. <h3>Conclusions</h3> Mechanical thrombectomy has become a widely used treatment option for acute intracranial large or medium vessel occlusion, using large-bore balloon guiding or aspiration catheters. However tortuous anatomy of the cervical arteries, in general the common and internal carotid artery may prevent advancing this large catheter towards the side of the occlusion and therefore impact the outcome of the patient. The iNedit distal balloon guide catheter (iVascular) used in this patient overcomes the very tortuous anatomy and made the intracranial mechanical thrombectomy successful with good clinical outcome. <h3>Conflict of Interest</h3> No

Authors

Institutions

Publication Details

Published
2025-09-01
DOI
https://doi.org/10.1136/jnis-2025-esmint.207
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

C74 Inedit (iVascular) distal balloon guide catheter overcomes tortuous and looped carotid artery during mechanical thrombectomy

Olivier François
Cerebrovascular and Carotid Artery Diseases
article

C74 Inedit (iVascular) distal balloon guide catheter overcomes tortuous and looped carotid artery during mechanical thrombectomy

Olivier François
article en

Abstract

<h3>Introduction</h3> Carotid artery tortuosity is a challange in the endovascular treatment of ischemic stroke patients, leading to technical failure in mechanical thrombectomy and potentialy worse outcome. Distal balloon guide catheters may overcome this obstacles <h3>Case Description</h3> An 83 y old woman suffered an acute ischemic stroke caused by an occlusion of the proximal M1 segment of the right middle cerebral artery. High ASPECT score and a favourable CT perfusion made her a good candidate for mechanical thrombectomy. However CT angiography demonstrated a type 3 aortic arch, a very tortuous common carotid artery and a looping (coiling) in the cervical segment of the right internal carotid artery. Through an 8 F long sheath in the brachiocephalic trunc, a 6 F distal balloon guide catheter (iNedit, iVascular) easily passed the carotid artery tortuosity (CAT) and looping in the internal carotid artery upon the cavernosal part of the carotid artery Succesfull mechanical thrombectomy with stentretriever under distal ballon occlusion was performed. <h3>Final angiographic result</h3> TICI 3 in one pass. <h3>Conclusions</h3> Mechanical thrombectomy has become a widely used treatment option for acute intracranial large or medium vessel occlusion, using large-bore balloon guiding or aspiration catheters. However tortuous anatomy of the cervical arteries, in general the common and internal carotid artery may prevent advancing this large catheter towards the side of the occlusion and therefore impact the outcome of the patient. The iNedit distal balloon guide catheter (iVascular) used in this patient overcomes the very tortuous anatomy and made the intracranial mechanical thrombectomy successful with good clinical outcome. <h3>Conflict of Interest</h3> No

AZ Groeninge (BE)
Openalex Percentile: Top 66%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.