Correlation of Pleural and Pulmonary Ultrasound with the Severity of Autoimmune Interstitial Lung Disease

Background/Aims: Interstitial lung disease is one of the most important complications in autoimmune diseases. The extent of involvement in tomography is crucial for therapeutic decision-making. Pleuropulmonary ultrasound is helpful in screening and correlates with severity. Using the Goh method, the objective is to analyze the correlation between ultrasound findings and the quantified extent on high-resolution computed tomography (HRCT). Materials and Methods: The HRCT images of patients with rheumatoid arthritis or systemic sclerosis were analyzed using the Goh method. The data were compared with the number of B-lines and ultrasound pleural abnormalities. The correlation was determined using Spearman's Rho statistic, and receiver operating characteristic curve analysis was performed. The sensitivity, specificity, and cutoff points were calculated for each ultrasound finding to detect severe disease. Results: A total of 71 patients were included. Almost half of the patients (56%) were involved in less than 5% of extent in HRCT; an average disease extent was 11% for the whole population. The correlation (Rho) between the extent and the total B-line count was 0.58 and 0.61 (P < .001), and for pleural abnormalities, 0.60 and 0.59 (P < .001) in linear and convex images, correspondingly. The areas under the curve were high for both ultrasound abnormalities and in both forms of images, consistently exceeding 0.7. Regarding the cutoff values, a number greater than 20 B-lines has a specificity close to 90% for detecting extensive disease, as well as 7 or more pleural abnormalities. Conclusion: The count of B-lines and the number of pleural abnormalities on lung ultrasound correlate well with the extent of the disease and can help determine its severity.

Authors

Institutions

Publication Details

Journal
Archives of Rheumatology
Published
2025-09-01
DOI
https://doi.org/10.5152/archrheumatol.2025.10999
Primary Topic
Medical Imaging and Pathology Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of Pleural and Pulmonary Ultrasound with the Severity of Autoimmune Interstitial Lung Disease

Luis Javier Cajas Santana, Gabriela Guerrero, Satiago Cuero, María Carolina Torres Villarreal et al.
1 links
Archives of Rheumatology
Medical Imaging and Pathology Studies
article

Correlation of Pleural and Pulmonary Ultrasound with the Severity of Autoimmune Interstitial Lung Disease

Luis Javier Cajas Santana, Gabriela Guerrero, Satiago Cuero, María Carolina Torres Villarreal, Mayelin Ceballos
article en

Abstract

Background/Aims: Interstitial lung disease is one of the most important complications in autoimmune diseases. The extent of involvement in tomography is crucial for therapeutic decision-making. Pleuropulmonary ultrasound is helpful in screening and correlates with severity. Using the Goh method, the objective is to analyze the correlation between ultrasound findings and the quantified extent on high-resolution computed tomography (HRCT). Materials and Methods: The HRCT images of patients with rheumatoid arthritis or systemic sclerosis were analyzed using the Goh method. The data were compared with the number of B-lines and ultrasound pleural abnormalities. The correlation was determined using Spearman's Rho statistic, and receiver operating characteristic curve analysis was performed. The sensitivity, specificity, and cutoff points were calculated for each ultrasound finding to detect severe disease. Results: A total of 71 patients were included. Almost half of the patients (56%) were involved in less than 5% of extent in HRCT; an average disease extent was 11% for the whole population. The correlation (Rho) between the extent and the total B-line count was 0.58 and 0.61 (P < .001), and for pleural abnormalities, 0.60 and 0.59 (P < .001) in linear and convex images, correspondingly. The areas under the curve were high for both ultrasound abnormalities and in both forms of images, consistently exceeding 0.7. Regarding the cutoff values, a number greater than 20 B-lines has a specificity close to 90% for detecting extensive disease, as well as 7 or more pleural abnormalities. Conclusion: The count of B-lines and the number of pleural abnormalities on lung ultrasound correlate well with the extent of the disease and can help determine its severity.

Archives of RheumatologyVol. 40(3)
Universidad Nacional de Colombia (CO), Hospital Universitario Nacional de Colombia (CO)
Openalex Percentile: Top 66%
Medical Imaging and Pathology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.