A Numerical Investigation of the Trade-Off Between Sound Insulation and Air Ventilation for a Partially Open Door

As urban buildings become increasingly dense, indoor personnel are often exposed to noise disturbances from adjoining rooms which can reduce working efficiency and affect mental health. Closing the door is one of the ways to reduce noise transmission, but it can cause a decrease in indoor air circulation. This paper investigates the sound insulation effect and air ventilation performance of a door in a partially open state by numerical simulation. To acquire the effect of sound insulation, an acoustic–structural solver is employed to calculate the sound transmission losses with different door opening angles in the frequency domain. To evaluate the ventilation performance, the mass flow rates across door opening are calculated by computational fluid dynamics. The simulation results confirm the trade-off relation between the sound insulation effect and the ventilation performance. To calculate the effect of noise and ventilation on work efficiency, a comprehensive evaluation index workplace environmental score (WES) was introduced and calculated by the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. A clear sound insulation effect corresponds to an opening angle (θd) of less than 15° with minimum air ventilation. Good ventilation performance could be obtained when the door opening angle is larger than 45°, while the sound insulation effect is negligible. A good compromise between the sound insulation effect and the air ventilation performance is found to be in the range of θd = 15°~25°, which provides practical recommendations in daily routines.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2025-09-03
DOI
https://doi.org/10.3390/eng6090223
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Numerical Investigation of the Trade-Off Between Sound Insulation and Air Ventilation for a Partially Open Door

Xu Li, Jizhou Liu, Jiying Liu, Ming Li
Eng—Advances in Engineering
Wind and Air Flow Studies
article

A Numerical Investigation of the Trade-Off Between Sound Insulation and Air Ventilation for a Partially Open Door

Xu Li, Jizhou Liu, Jiying Liu, Ming Li
article en

Abstract

As urban buildings become increasingly dense, indoor personnel are often exposed to noise disturbances from adjoining rooms which can reduce working efficiency and affect mental health. Closing the door is one of the ways to reduce noise transmission, but it can cause a decrease in indoor air circulation. This paper investigates the sound insulation effect and air ventilation performance of a door in a partially open state by numerical simulation. To acquire the effect of sound insulation, an acoustic–structural solver is employed to calculate the sound transmission losses with different door opening angles in the frequency domain. To evaluate the ventilation performance, the mass flow rates across door opening are calculated by computational fluid dynamics. The simulation results confirm the trade-off relation between the sound insulation effect and the ventilation performance. To calculate the effect of noise and ventilation on work efficiency, a comprehensive evaluation index workplace environmental score (WES) was introduced and calculated by the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. A clear sound insulation effect corresponds to an opening angle (θd) of less than 15° with minimum air ventilation. Good ventilation performance could be obtained when the door opening angle is larger than 45°, while the sound insulation effect is negligible. A good compromise between the sound insulation effect and the air ventilation performance is found to be in the range of θd = 15°~25°, which provides practical recommendations in daily routines.

Eng—Advances in EngineeringVol. 6(9)
Shandong Jianzhu University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 79%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.