Evaluation of mandibular bone abnormalities in patients with chronic kidney disease using cone beam computed tomography: A retrospective study
Although findings should be interpreted considering the retrospective design's limitations, CBCT revealed significant bone abnormalities in CKD patients, with compromised bone quality and reduced mandibular cortical thickness, especially in advanced renal impairment, suggesting its value for pre-implant bone quality assessment in CKD patients.
Authors
- Jae-Suk Jung (ORCID: https://orcid.org/0000-0002-2018-6450)
- J. B. Lee (ORCID: https://orcid.org/0009-0009-4319-3926)
- Suk Ji (ORCID: https://orcid.org/0000-0001-9720-6731)
- Inwhee Park (ORCID: https://orcid.org/0000-0002-9912-5393)
- Jeong Keun Lee
- H Lee (ORCID: https://orcid.org/0000-0003-1880-9695)
- Bumhee Park (ORCID: https://orcid.org/0000-0002-5271-1571)
- Seung Il Song (ORCID: https://orcid.org/0000-0001-9504-6471)
- Ji Min Kim
Institutions
- Ajou University (KR)
Publication Details
- Journal
- Acta Odontologica Scandinavica
- Published
- 2025-09-03
- DOI
- https://doi.org/10.2340/aos.v84.44619
- Citations
- 1
- Primary Topic
- Dental Radiography and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 1.79
Funders
- Ajou University
- Korea Health Industry Development Institute