Evaluation of loop-mediated isothermal amplification (LAMP) assay for detection of five bacterial periprosthetic joint infection
Objectives: Periprosthetic joint infection (PJI) is one of the most serious and debilitating complications that can occur after total joint arthroplasty. Therefore, early diagnosis and appropriate treatment are important for a good prognosis. Recently, molecular diagnostic methods have been widely used to detect the causative microorganisms of PJI sensitively and rapidly. The Multiplex Loop- Mediated Isothermal Amplification (LAMP) method is faster and easier to perform compared to polymerase chain reaction (PCR)-based assays. Therefore, this study developed a multiplex LAMP assay for diagnosing bacterial PJI using LAMP technology and evaluated its analytical and clinical performance. Methods: We developed a multiplex LAMP assay for the detection of five bacteria: Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus agalactiae, Pseudomonas aeruginosa, and Escherichia coli, frequently observed to be the causative agents of PJI. The method limit of detection (LOD) and cross-reactivity were determined by spiking standard strains into the joint synovial fluid. The LOD of the multiplex LAMP assay was compared with that of a quantitative real-time PCR (qPCR) assay. Clinical performance was evaluated using 20 joint synovial fluid samples collected from patients suspected of having bacterial PJI. Results: The LOD of the gram-positive bacterial multiplex LAMP assay and qPCR were 10 5 /10 4 CFU/mL, 10 3 /10 3 CFU/mL, and 10 5 /10 4 CFU/mL against S. agalactiae , S. epidermidis, and S. aureus , respectively. For P. aeruginosa and E. coli , the LOD of the multiplex LAMP and qPCR assays were 10 5 /10 4 and 10 6 /10 4 CFU/mL, respectively. The multiplex LAMP assay detects target bacteria without cross-reacting with other bacteria, and exhibited 100% sensitivity and specificity in clinical performance evaluation. Conclusions: This multiplex LAMP assay can rapidly detect five high-prevalence bacterial species causing bacterial PJI, with excellent sensitivity and specificity, in less than 1 h, and it may be useful for the early diagnosis of PJI.
Authors
- Ji‐Hoon Bae (ORCID: https://orcid.org/0000-0002-6390-0378)
- Chae Seung Lim (ORCID: https://orcid.org/0000-0002-7765-0840)
- Woong Sik Jang (ORCID: https://orcid.org/0000-0002-2910-0537)
- Min Cho (ORCID: https://orcid.org/0000-0002-0609-7734)
Institutions
- Korea University (KR)
Publication Details
- Journal
- Antimicrobial Stewardship & Healthcare Epidemiology
- Published
- 2025-05-01
- DOI
- https://doi.org/10.1017/ash.2025.158
- Primary Topic
- Orthopedic Infections and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00