Oxygen as an Insufflation Gas During Laparoscopy

Introduction: There are sudden and unreported deaths from laparoscopic procedures due to the side effects of CO2 insufflation, such as hypercarbia. Materials and Methods: In the last 10 years, 758 laparoscopy cases have been performed using oxygen as an insufflation gas instead of CO2. In a closed glass bottle, chicken meat placed over a cautery pad was cauterized under 100% oxygen, did not have any sparks or explosions, and a study was done before trying on humans. Results: Only 7 patients had peritonism, and the mortality rate was zero. Discussion: Oxygen is a medium and not a fuel, such as methane or hydrogen, and hence, it cannot burn by itself, leading to an explosion. Electrocautery can be used with O2, without risks. CO2 leads to hypercarbia, with risk to two extremes of age. Conclusion: The use of oxygen in Laparoscopy was safe and effective, even with the use of electrocautery.

Authors

Institutions

Publication Details

Journal
European Journal of Medical and Health Sciences
Published
2025-08-31
DOI
https://doi.org/10.24018/ejmed.2025.7.4.2344
Primary Topic
Abdominal Surgery and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oxygen as an Insufflation Gas During Laparoscopy

Sagar Jawale
European Journal of Medical and Health Sciences
Abdominal Surgery and Complications
article

Oxygen as an Insufflation Gas During Laparoscopy

Sagar Jawale
article en

Abstract

Introduction: There are sudden and unreported deaths from laparoscopic procedures due to the side effects of CO2 insufflation, such as hypercarbia. Materials and Methods: In the last 10 years, 758 laparoscopy cases have been performed using oxygen as an insufflation gas instead of CO2. In a closed glass bottle, chicken meat placed over a cautery pad was cauterized under 100% oxygen, did not have any sparks or explosions, and a study was done before trying on humans. Results: Only 7 patients had peritonism, and the mortality rate was zero. Discussion: Oxygen is a medium and not a fuel, such as methane or hydrogen, and hence, it cannot burn by itself, leading to an explosion. Electrocautery can be used with O2, without risks. CO2 leads to hypercarbia, with risk to two extremes of age. Conclusion: The use of oxygen in Laparoscopy was safe and effective, even with the use of electrocautery.

European Journal of Medical and Health SciencesVol. 7(4)
Jawaharlal Nehru Cancer Hospital and Research Centre (IN)
Openalex Percentile: Top 66%
Abdominal Surgery and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.