Retrospectively synchronized time‐resolved ventricular cine images from 2D real‐time exercise cardiac magnetic resonance imaging

Breath-hold ECG-gated cardiovascular magnetic resonance (CMR) imaging is challenging during exercise due to motion, ECG-problems, and lengthy scans. To facilitate time-resolved volumetric measures from exercise-CMR, we aimed to develop a method for constructing time-resolved ventricular cines from real-time free-breathing exercise-CMR. Time-resolved ventricular cines were semi-automatically constructed from real-time exercise-CMR by identifying end-expiratory timeframes, identifying one R-R interval within these timeframes, and synchronizing R-R intervals across slice positions. To investigate utility, ECG-gated rest CMR and real-time exercise-CMR images were collected from ten healthy volunteers and ten heart failure patients. The consistency of the left ventricular mass (LVM) was assessed between rest and exercise at end diastole (ED), mid systole (MS), end systole (ES), and early rapid filling (ERF). When comparing LVM between rest and exercise for healthy volunteers, bias ± SD was 1.5 ± 2.7 g at ED, 0.9 ± 3.3 g at MS, 1.3 ± 3.3 g at ES, and 1.2 ± 3.3 g at ERF. When comparing LVM between rest and exercise for heart failure patients, bias ± SD was 1.6 ± 2.8 g at ED, 1.0 ± 2.7 g at MS, 1.5 ± 2.6 g at ES, and 1.6 ± 2.5 g at ERF. The bias ± SD between ED and ES in standard rest images was 0.0 ± 0.7 g for healthy volunteers, and 0.0 ± 0.5 g for heart failure patients. The method for constructing time-resolved ventricular cines from real-time exercise-CMR demonstrated utility for time-resolved volumetric measurements in healthy volunteers and heart failure patients.

Authors

Institutions

Publication Details

Journal
Clinical Physiology and Functional Imaging
Published
2025-09-01
DOI
https://doi.org/10.1111/cpf.70027
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrospectively synchronized time‐resolved ventricular cine images from 2D real‐time exercise cardiac magnetic resonance imaging

Jonathan Edlund, Einar Heiberg, Katarina Steding‐Ehrenborg, Julius Åkesson
1 citations
Clinical Physiology and Functional Imaging
Advanced MRI Techniques and Applications
1.36
article

Retrospectively synchronized time‐resolved ventricular cine images from 2D real‐time exercise cardiac magnetic resonance imaging

Jonathan Edlund, Einar Heiberg, Katarina Steding‐Ehrenborg, Julius Åkesson
article en
1 citations

Abstract

Breath-hold ECG-gated cardiovascular magnetic resonance (CMR) imaging is challenging during exercise due to motion, ECG-problems, and lengthy scans. To facilitate time-resolved volumetric measures from exercise-CMR, we aimed to develop a method for constructing time-resolved ventricular cines from real-time free-breathing exercise-CMR. Time-resolved ventricular cines were semi-automatically constructed from real-time exercise-CMR by identifying end-expiratory timeframes, identifying one R-R interval within these timeframes, and synchronizing R-R intervals across slice positions. To investigate utility, ECG-gated rest CMR and real-time exercise-CMR images were collected from ten healthy volunteers and ten heart failure patients. The consistency of the left ventricular mass (LVM) was assessed between rest and exercise at end diastole (ED), mid systole (MS), end systole (ES), and early rapid filling (ERF). When comparing LVM between rest and exercise for healthy volunteers, bias ± SD was 1.5 ± 2.7 g at ED, 0.9 ± 3.3 g at MS, 1.3 ± 3.3 g at ES, and 1.2 ± 3.3 g at ERF. When comparing LVM between rest and exercise for heart failure patients, bias ± SD was 1.6 ± 2.8 g at ED, 1.0 ± 2.7 g at MS, 1.5 ± 2.6 g at ES, and 1.6 ± 2.5 g at ERF. The bias ± SD between ED and ES in standard rest images was 0.0 ± 0.7 g for healthy volunteers, and 0.0 ± 0.5 g for heart failure patients. The method for constructing time-resolved ventricular cines from real-time exercise-CMR demonstrated utility for time-resolved volumetric measurements in healthy volunteers and heart failure patients.

Clinical Physiology and Functional ImagingVol. 45(5)
Lund University (SE), Skåne University Hospital (SE)
Vetenskapsrådet, Wallenberg Centre for Molecular and Translational Medicine
Openalex Percentile: Top 16%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.