Multiband cross-fractal antenna integrated with SRR metamaterials for high-sensitivity liquid characterization and optimal frequency band identification

Abstract This study presents a novel compact planar antenna based on cross-fractal geometry integrated with square split-ring resonator (SRR) metamaterials for advanced multiband liquid characterization and optimal frequency band detection. The proposed sensor synergistically combines the space-filling properties of fractal structures with the electromagnetic field enhancement capabilities of metamaterials to achieve exceptional sensitivity across a broad 1−10 GHz frequency range while maintaining an ultra-compact (10 × 10) mm 2 footprint, which corresponds to wavelength dimensions the order of 0.013 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> × 0.013 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> (where <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> is the free-space wavelength calculated at the lowest operating frequency), and demonstrates a high gain of 4.28 dBi. The SRR metamaterial integration significantly enhances frequency selectivity and field confinement, resulting in an impressive S 11 variation of −23 dB and a remarkable sensitivity of 300 MHz when tested with deionized water-representing a 50-fold improvement over existing sensors. A key innovation lies in the systematic identification of the optimal frequency band through comprehensive multiband analysis, where experimental validation using pure water, pure ethanol, and water-ethanol mixtures reveals that the 5 GHz band exhibits the highest sensitivity to dielectric property variations. The sensor requires only ∼100 mm 3 of test liquid, enabling point-of-care applications with limited sample availability, while rigorous evaluation of sample holder configurations ensures minimal measurement perturbations and optimal accuracy. Comparative analysis demonstrates superior performance over existing fractal and metamaterial-based biosensors in sensitivity (300 MHz versus 0.4–0.7 MHz) with a bandwidth fraction of 54.54%, sample volume requirement (100 mm 3 versus 300–5000 mm 3 ), operational bandwidth (multiband versus narrow sub-bands), and gain (4.28 dBi versus 2.28–3.15 dB). The standard printed circuit board (PCB) fabrication process ensures cost-effectiveness and scalability, while vector network analyzer calibration and excellent agreement between simulated and experimental results validate the design’s reliability. This work establishes a new benchmark for compact, high-sensitivity microwave sensors and provides valuable insights for frequency band selection optimization, with significant implications for next-generation biosensors in medical diagnostics, chemical analysis, and environmental monitoring applications.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-09-01
DOI
https://doi.org/10.1088/1402-4896/ae01fb
Citations
1
Primary Topic
Antenna Design and Analysis
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiband cross-fractal antenna integrated with SRR metamaterials for high-sensitivity liquid characterization and optimal frequency band identification

Junwu Tao, Ibrahim Mahariq, Zinelabiddine Mezache, Nourelhouda Dadouche et al.
1 citations
Physica Scripta
Antenna Design and Analysis
4.99
article

Multiband cross-fractal antenna integrated with SRR metamaterials for high-sensitivity liquid characterization and optimal frequency band identification

Junwu Tao, Ibrahim Mahariq, Zinelabiddine Mezache, Nourelhouda Dadouche, Mohammed Berka
article en
1 citations

Abstract

Abstract This study presents a novel compact planar antenna based on cross-fractal geometry integrated with square split-ring resonator (SRR) metamaterials for advanced multiband liquid characterization and optimal frequency band detection. The proposed sensor synergistically combines the space-filling properties of fractal structures with the electromagnetic field enhancement capabilities of metamaterials to achieve exceptional sensitivity across a broad 1−10 GHz frequency range while maintaining an ultra-compact (10 × 10) mm 2 footprint, which corresponds to wavelength dimensions the order of 0.013 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> × 0.013 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> (where <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msub> <mml:mrow> <mml:mi>λ</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>0</mml:mn> </mml:mrow> </mml:msub> </mml:math> is the free-space wavelength calculated at the lowest operating frequency), and demonstrates a high gain of 4.28 dBi. The SRR metamaterial integration significantly enhances frequency selectivity and field confinement, resulting in an impressive S 11 variation of −23 dB and a remarkable sensitivity of 300 MHz when tested with deionized water-representing a 50-fold improvement over existing sensors. A key innovation lies in the systematic identification of the optimal frequency band through comprehensive multiband analysis, where experimental validation using pure water, pure ethanol, and water-ethanol mixtures reveals that the 5 GHz band exhibits the highest sensitivity to dielectric property variations. The sensor requires only ∼100 mm 3 of test liquid, enabling point-of-care applications with limited sample availability, while rigorous evaluation of sample holder configurations ensures minimal measurement perturbations and optimal accuracy. Comparative analysis demonstrates superior performance over existing fractal and metamaterial-based biosensors in sensitivity (300 MHz versus 0.4–0.7 MHz) with a bandwidth fraction of 54.54%, sample volume requirement (100 mm 3 versus 300–5000 mm 3 ), operational bandwidth (multiband versus narrow sub-bands), and gain (4.28 dBi versus 2.28–3.15 dB). The standard printed circuit board (PCB) fabrication process ensures cost-effectiveness and scalability, while vector network analyzer calibration and excellent agreement between simulated and experimental results validate the design’s reliability. This work establishes a new benchmark for compact, high-sensitivity microwave sensors and provides valuable insights for frequency band selection optimization, with significant implications for next-generation biosensors in medical diagnostics, chemical analysis, and environmental monitoring applications.

Physica ScriptaVol. 100(9)
Applied Science Private University (JO), China Medical University (TW), Institut National Polytechnique de Toulouse (FR), Al-Quds University (PS), University Ferhat Abbas of Setif (DZ), Laboratoire Plasma et Conversion d'Energie (FR), Université Mustapha Stambouli de Mascara (DZ), Université Djilali de Sidi Bel Abbès (DZ), China Medical University Hospital (TW), Korea University (JP), École Nationale Supérieure d'Électrotechnique, d'Électronique, d'Informatique, d'Hydraulique et des Télécommunications (FR)
Openalex Percentile: Top 5%
Antenna Design and Analysis
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.