Polymeric Membrane Electrodes for a Fast End Cost-Effective Potentiometric Determination of Octenidine Dihydrochloride in Pharmaceutical Samples

Determining the active substance content in the tested product is an essential part of research for overall assessment of the quality of a medicinal substance. This role can be successfully performed by membrane electrodes that are selective for a specific drug. The novelty of the presented research is the development of the first ion-selective electrode with a polymer membrane phase with the octenidine (OCT) function. Classical ion-selective electrodes (ISE), polymer electrodes with an internal Ag/AgCl electrode, and electrode bodies with glassy carbon were used for the research. The membranes were prepared based on cation exchangers from the borate group and neutral cyclodextrin. All sensors have good parameters, e.g., the polymer electrode with KtpClPB is characterised by a wide linear range of -logc 6-3, a low limit of detection 5 × 10<sup>-7</sup> M, and a near-Nernstian, reproducible slope of characteristics of 31.41 ± 1.14 mV/decade. It can be seen that a stable, reversible potential and a short response time were achieved for this sensor. The obtained favourable selectivity coefficients of the electrode determined in relation to excipients allowed direct determination of octenidine, e.g., in lozenges. The results obtained with the calibration curve method show a recovery of 97% and a precision of SD 2.3 mg/L, which indicates that the data are consistent with the pharmacopoeia requirements.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-09-01
DOI
https://doi.org/10.3390/ma18174100
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polymeric Membrane Electrodes for a Fast End Cost-Effective Potentiometric Determination of Octenidine Dihydrochloride in Pharmaceutical Samples

Joanna Lenik
Materials
Analytical Chemistry and Sensors
article

Polymeric Membrane Electrodes for a Fast End Cost-Effective Potentiometric Determination of Octenidine Dihydrochloride in Pharmaceutical Samples

Joanna Lenik
article en

Abstract

Determining the active substance content in the tested product is an essential part of research for overall assessment of the quality of a medicinal substance. This role can be successfully performed by membrane electrodes that are selective for a specific drug. The novelty of the presented research is the development of the first ion-selective electrode with a polymer membrane phase with the octenidine (OCT) function. Classical ion-selective electrodes (ISE), polymer electrodes with an internal Ag/AgCl electrode, and electrode bodies with glassy carbon were used for the research. The membranes were prepared based on cation exchangers from the borate group and neutral cyclodextrin. All sensors have good parameters, e.g., the polymer electrode with KtpClPB is characterised by a wide linear range of -logc 6-3, a low limit of detection 5 × 10<sup>-7</sup> M, and a near-Nernstian, reproducible slope of characteristics of 31.41 ± 1.14 mV/decade. It can be seen that a stable, reversible potential and a short response time were achieved for this sensor. The obtained favourable selectivity coefficients of the electrode determined in relation to excipients allowed direct determination of octenidine, e.g., in lozenges. The results obtained with the calibration curve method show a recovery of 97% and a precision of SD 2.3 mg/L, which indicates that the data are consistent with the pharmacopoeia requirements.

MaterialsVol. 18(17)
Maria Curie-Skłodowska University (PL)
Openalex Percentile: Top 69%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.