Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius

Dielectric strength is a very important parameter for cables. It can vary according to temperature and frequency. The complex electrical permittivity of the Cross-linked polyethylene (XLPE) and Copper Polyester/Mylar band layers of a cable determine the maximum electric field created inside the cable operating at sinusoidal voltage. The value of this electric field should be less than the dielectric strength of the materials used. The electrical characteristics of XLPE and Copper Polyester tape depend on frequency and temperature. In a power cable, the temperature depends on the radial position, which makes it difficult to calculate the cable’s electric field. In this study, it was shown how to calculate the electric field of the cable by using XLPE and Copper Polyester band data taken from the literature and numerical integration. It was found that the calculated value is less than the Dielectric strength value of XLPE material. It has been shown how the electric field of the power cable under investigation changes according to frequency and temperature.

Authors

Institutions

Publication Details

Journal
Journal of Engineering Technology and Applied Sciences
Published
2025-08-30
DOI
https://doi.org/10.30931/jetas.1404278
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius

Reşat MUTLU, Rabia Korkmaz Tan, Hafız ALİSOY, Hakan Çanta
Journal of Engineering Technology and Applied Sciences
Thermal Analysis in Power Transmission
article

Evaluation of the Electric Field of a Single-Core Power Cable at the Inner Conductor Radius

Reşat MUTLU, Rabia Korkmaz Tan, Hafız ALİSOY, Hakan Çanta
article en

Abstract

Dielectric strength is a very important parameter for cables. It can vary according to temperature and frequency. The complex electrical permittivity of the Cross-linked polyethylene (XLPE) and Copper Polyester/Mylar band layers of a cable determine the maximum electric field created inside the cable operating at sinusoidal voltage. The value of this electric field should be less than the dielectric strength of the materials used. The electrical characteristics of XLPE and Copper Polyester tape depend on frequency and temperature. In a power cable, the temperature depends on the radial position, which makes it difficult to calculate the cable’s electric field. In this study, it was shown how to calculate the electric field of the cable by using XLPE and Copper Polyester band data taken from the literature and numerical integration. It was found that the calculated value is less than the Dielectric strength value of XLPE material. It has been shown how the electric field of the power cable under investigation changes according to frequency and temperature.

Journal of Engineering Technology and Applied SciencesVol. 10(2)
Tekirdağ Namık Kemal University (TR), Setas (Turkey) (TR)
Openalex Percentile: Top 72%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.