Numerical and Experimental Performance Assessment of Helical Screw Inserts in a Horizontal Evaporator Tube

The influence of a helical screw insert on heat transfer and pressure drop in a circular tube under single-phase water flow conditions was investigated using both experimental techniques and CFD simulations with ANSYS Fluent. Experiments were conducted with water flowing through a horizontally oriented copper tube located in a pressurized tank, across seven different Reynolds numbers ranging from 24,000 to 100,000. A constant surface temperature was maintained via saturated pool boiling of R134a surrounding the tube. The internal flow characteristics were assessed based on measured pressure, temperature, and flow rate data, with convective heat transfer coefficients evaluated using the Wilson plot method. Simulations were conducted for both plain and insert-equipped tubes under identical conditions. The results for the helical insert case aligned well with experimental observations. Compared to literature correlations, heat transfer results were similar, though friction factor predictions were underestimated. A 19% improvement in heat transfer was observed with the insert, accompanied by a significant increase in pressure drop.

Authors

Institutions

Publication Details

Journal
International Journal of Thermodynamics
Published
2025-09-01
DOI
https://doi.org/10.5541/ijot.1702193
Primary Topic
Heat transfer and supercritical fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and Experimental Performance Assessment of Helical Screw Inserts in a Horizontal Evaporator Tube

Yalçın Uralcan, İbrahim Hakkı Tonyalı
5 links
International Journal of Thermodynamics
Heat transfer and supercritical fluids
article

Numerical and Experimental Performance Assessment of Helical Screw Inserts in a Horizontal Evaporator Tube

Yalçın Uralcan, İbrahim Hakkı Tonyalı
article en

Abstract

The influence of a helical screw insert on heat transfer and pressure drop in a circular tube under single-phase water flow conditions was investigated using both experimental techniques and CFD simulations with ANSYS Fluent. Experiments were conducted with water flowing through a horizontally oriented copper tube located in a pressurized tank, across seven different Reynolds numbers ranging from 24,000 to 100,000. A constant surface temperature was maintained via saturated pool boiling of R134a surrounding the tube. The internal flow characteristics were assessed based on measured pressure, temperature, and flow rate data, with convective heat transfer coefficients evaluated using the Wilson plot method. Simulations were conducted for both plain and insert-equipped tubes under identical conditions. The results for the helical insert case aligned well with experimental observations. Compared to literature correlations, heat transfer results were similar, though friction factor predictions were underestimated. A 19% improvement in heat transfer was observed with the insert, accompanied by a significant increase in pressure drop.

International Journal of ThermodynamicsVol. 28(3)
Istanbul Technical University (TR)
Openalex Percentile: Top 75%
Heat transfer and supercritical fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.