Exergetic Evaluation of Heat Exchanger with Multiple Inserts for Greenhouse Heating

The heat exchanger performance is vital for attaining higher overall performance of the greenhouse heating system. The exergetic performance is evaluated for the heat exchanger using twisted tape inserts for greenhouse heating. Single, a set of two, and four twisted tapes of TR 2.5-3.5 are considered for the analysis by varying Reynolds number (Re) from 3000 to 15000. A set of two twisted tapes causes a decrease in total entropy generation up to Re of 7650 and increases beyond this value. The maximum and minimum values of the Bejan number are obtained for the smooth tube and the tube with twisted tapes (four) in “counter-swirl” orientation, respectively. The twisted tapes are feasible under the Reynolds number of 9042 based on the analysis of the entropy generation number. The minimum value of total entropy generation is obtained as 0.00035 for the four twisted tapes in counter-swirl orientation (FTT-COUS). The maximum exergy efficiency is observed for a twisted tape insert at a pitch ratio of 3.5.

Authors

Institutions

Publication Details

Journal
International Journal of Thermodynamics
Published
2025-09-01
DOI
https://doi.org/10.5541/ijot.1514519
Primary Topic
Greenhouse Technology and Climate Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergetic Evaluation of Heat Exchanger with Multiple Inserts for Greenhouse Heating

Anil Kumar Patil, Manoj Kumar
International Journal of Thermodynamics
Greenhouse Technology and Climate Control
article

Exergetic Evaluation of Heat Exchanger with Multiple Inserts for Greenhouse Heating

Anil Kumar Patil, Manoj Kumar
article en

Abstract

The heat exchanger performance is vital for attaining higher overall performance of the greenhouse heating system. The exergetic performance is evaluated for the heat exchanger using twisted tape inserts for greenhouse heating. Single, a set of two, and four twisted tapes of TR 2.5-3.5 are considered for the analysis by varying Reynolds number (Re) from 3000 to 15000. A set of two twisted tapes causes a decrease in total entropy generation up to Re of 7650 and increases beyond this value. The maximum and minimum values of the Bejan number are obtained for the smooth tube and the tube with twisted tapes (four) in “counter-swirl” orientation, respectively. The twisted tapes are feasible under the Reynolds number of 9042 based on the analysis of the entropy generation number. The minimum value of total entropy generation is obtained as 0.00035 for the four twisted tapes in counter-swirl orientation (FTT-COUS). The maximum exergy efficiency is observed for a twisted tape insert at a pitch ratio of 3.5.

International Journal of ThermodynamicsVol. 28(3)
Dehradun Institute of Technology University (IN)
Openalex Percentile: Top 83%
Greenhouse Technology and Climate Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exergetic Evaluation of Heat Exchanger with Multiple Inserts for Greenhouse Heating — Anil Kumar Patil, Manoj Kumar · International Journal of Thermodynamics (2025) | TGRS Research Map | TGRS