Anatomical Lens Position Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery

<b>Objectives</b>: To assess the anatomical lens position (ALP) predictability for a capsulotomy-fixated intraocular lens (IOL; FEMTIS FB-313, Teleon Surgical B.V) versus an intracapsular IOL (TECNIS 1-Piece, ZCB00V, Johnson & Johnson) implanted for age-related cataracts. <b>Methods</b>: Pre- and 3-month postoperative measurements from optical biometry and swept-source anterior segment OCT were analyzed. The lens position (<i>i.e.</i>, postoperatively, ALP) was defined as the distance between the corneal endothelium and the lens equator. Multivariate linear mixed-effects models assessed the influence of preoperative biometric parameters on ALP, prediction error (PE), and absolute PE (AbsPE). <b>Results</b>: A total of 45 FEMTIS eyes from 32 patients and 26 TECNIS eyes from 18 patients were included. Postoperatively, the anterior chamber depth (ACD) increased by 1.10 mm in FEMTIS eyes and 1.66 mm in TECNIS eyes, while the lens position decreased by 0.59 mm and 0.34 mm, respectively. ACD and lens thickness (LT) were the strongest ALP predictors (ACD: β = +0.70, <i>p</i> < 0.0001; LT: β = +0.37, <i>p</i> < 0.0001). Separate multivariate models demonstrated strong predictive performance, with the FEMTIS achieving R<sup>2</sup> = 0.92 and the TECNIS IOL performing even better with R<sup>2</sup> = 0.97. In the FEMTIS group, LT influenced the PE (<i>p</i> = 0.006) and ACD the AbsPE (<i>p</i> = 0.005). In the TECNIS group, ACD influenced the PE (<i>p</i> < 0.0001), while AbsPE was not significantly affected by biometric parameters or formulas. <b>Conclusions</b>: ALP can be reliably predicted from standard biometric data, although less accurately for the FEMTIS IOL. Its anterior capsulotomy fixation likely compromises refractive accuracy with formulas inherently designed and optimized for in-the-bag IOLs, emphasizing the need for fixation-specific formula adjustments and dedicated optimization in capsulotomy-fixated IOLs.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-08-30
DOI
https://doi.org/10.3390/jcm14176151
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anatomical Lens Position Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery

Philip Wakili, Colya N. Englisch, André Messias, Achim Langenbucher et al.
Journal of Clinical Medicine
Intraocular Surgery and Lenses
article

Anatomical Lens Position Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery

Philip Wakili, Colya N. Englisch, André Messias, Achim Langenbucher, Annekatrin Rickmann, Karl Boden, Anna Theresa Lorenz, Berthold Seitz, Clemens Niklas Rudolph, Peter Szurman
article en

Abstract

<b>Objectives</b>: To assess the anatomical lens position (ALP) predictability for a capsulotomy-fixated intraocular lens (IOL; FEMTIS FB-313, Teleon Surgical B.V) versus an intracapsular IOL (TECNIS 1-Piece, ZCB00V, Johnson & Johnson) implanted for age-related cataracts. <b>Methods</b>: Pre- and 3-month postoperative measurements from optical biometry and swept-source anterior segment OCT were analyzed. The lens position (<i>i.e.</i>, postoperatively, ALP) was defined as the distance between the corneal endothelium and the lens equator. Multivariate linear mixed-effects models assessed the influence of preoperative biometric parameters on ALP, prediction error (PE), and absolute PE (AbsPE). <b>Results</b>: A total of 45 FEMTIS eyes from 32 patients and 26 TECNIS eyes from 18 patients were included. Postoperatively, the anterior chamber depth (ACD) increased by 1.10 mm in FEMTIS eyes and 1.66 mm in TECNIS eyes, while the lens position decreased by 0.59 mm and 0.34 mm, respectively. ACD and lens thickness (LT) were the strongest ALP predictors (ACD: β = +0.70, <i>p</i> < 0.0001; LT: β = +0.37, <i>p</i> < 0.0001). Separate multivariate models demonstrated strong predictive performance, with the FEMTIS achieving R<sup>2</sup> = 0.92 and the TECNIS IOL performing even better with R<sup>2</sup> = 0.97. In the FEMTIS group, LT influenced the PE (<i>p</i> = 0.006) and ACD the AbsPE (<i>p</i> = 0.005). In the TECNIS group, ACD influenced the PE (<i>p</i> < 0.0001), while AbsPE was not significantly affected by biometric parameters or formulas. <b>Conclusions</b>: ALP can be reliably predicted from standard biometric data, although less accurately for the FEMTIS IOL. Its anterior capsulotomy fixation likely compromises refractive accuracy with formulas inherently designed and optimized for in-the-bag IOLs, emphasizing the need for fixation-specific formula adjustments and dedicated optimization in capsulotomy-fixated IOLs.

Journal of Clinical MedicineVol. 14(17)
Hess (United States) (US), Universidade de São Paulo (BR), Knappschaftsklinikum Saar (DE), Saarland University (DE)
Openalex Percentile: Top 65%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.