Rutherford backscattering spectrometry: A multimodal ion beam analysis technique for evaluating elemental depth profiles and radiation hardness for space photovoltaics applications

Given the well-established possibility of elemental migration in perovskite devices, often driven by multiple stressors and contributing to device degradation, it is essential to evaluate and quantify their elemental distribution using characterization techniques that minimize measurement-induced inter-mixing of elements. Techniques like time-of-flight secondary ion mass spectrometry and x-ray photoelectron spectroscopy based depth profiling are commonly employed for such analysis. However, despite their feasibility and effectiveness, these methods can inadvertently cause additional damage to the delicate perovskite as well as other organic structures present in the devices, which are vulnerable to preferential elemental sputtering and compositional matrix mixing effects. Such issues can lead to quantification errors and unwanted artifacts, particularly when using keV-range heavy ions such as Ar+, O+, Cs+, or Ar cluster ions for sputtering. In contrast, Rutherford Backscattering Spectrometry (RBS) utilizing MeV range energetic He or H ions is generally regarded as a non-destructive technique that does not require reference standards or extensive sample preparation. It provides a comprehensive analysis of the composition, thickness, and depth profiles of the elements present in the device layers, while also enabling a concurrent evaluation of radiation tolerance with the probing light ion beam (e.g., H+ and He+). This perspective highlights the key benefits of using RBS for elemental depth profiling and migration in perovskite-based devices and explores recent developments, ongoing challenges, and efforts toward achieving accurate quantitative analysis in complex multilayer thin-film structures.

Authors

Institutions

Publication Details

Journal
APL Energy
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0288594
Citations
3
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rutherford backscattering spectrometry: A multimodal ion beam analysis technique for evaluating elemental depth profiles and radiation hardness for space photovoltaics applications

Todd A. Byers, Mohin Sharma, Mritunjaya Parashar, Darshpreet Kaur Saini et al.
3 citations
APL Energy
Advanced Semiconductor Detectors and Materials
2.19
article

Rutherford backscattering spectrometry: A multimodal ion beam analysis technique for evaluating elemental depth profiles and radiation hardness for space photovoltaics applications

Todd A. Byers, Mohin Sharma, Mritunjaya Parashar, Darshpreet Kaur Saini, Bibhudutta Rout
article en
3 citations

Abstract

Given the well-established possibility of elemental migration in perovskite devices, often driven by multiple stressors and contributing to device degradation, it is essential to evaluate and quantify their elemental distribution using characterization techniques that minimize measurement-induced inter-mixing of elements. Techniques like time-of-flight secondary ion mass spectrometry and x-ray photoelectron spectroscopy based depth profiling are commonly employed for such analysis. However, despite their feasibility and effectiveness, these methods can inadvertently cause additional damage to the delicate perovskite as well as other organic structures present in the devices, which are vulnerable to preferential elemental sputtering and compositional matrix mixing effects. Such issues can lead to quantification errors and unwanted artifacts, particularly when using keV-range heavy ions such as Ar+, O+, Cs+, or Ar cluster ions for sputtering. In contrast, Rutherford Backscattering Spectrometry (RBS) utilizing MeV range energetic He or H ions is generally regarded as a non-destructive technique that does not require reference standards or extensive sample preparation. It provides a comprehensive analysis of the composition, thickness, and depth profiles of the elements present in the device layers, while also enabling a concurrent evaluation of radiation tolerance with the probing light ion beam (e.g., H+ and He+). This perspective highlights the key benefits of using RBS for elemental depth profiling and migration in perovskite-based devices and explores recent developments, ongoing challenges, and efforts toward achieving accurate quantitative analysis in complex multilayer thin-film structures.

APL EnergyVol. 3(3)
University of North Texas (US)
National Science Foundation
Openalex Percentile: Top 11%
Advanced Semiconductor Detectors and Materials
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.