Integrated Nanosecond Pulse Irreversible Electroporation (INSPIRE): Impact of Exposed Electrode Length on Ablation Geometry in an In Vivo Liver Model

<b>Objectives:</b> There is a critical need for effective focal therapies for patients with inoperable or anatomically complex tumors where conventional ablation techniques pose high risk or are ineffective. Integrated Nanosecond Pulsed Irreversible Electroporation (INSPIRE) is a novel non-thermal ablation modality which uses real time temperature feedback during pulse delivery to safely treat tumors near critical structures. This study evaluated the impact of exposed electrode length on ablation zone size, reproducibility, and cardiac safety in a large animal model. <b>Methods:</b> INSPIRE treatments were performed in an in vivo healthy porcine liver model. All treatments administered 6000 V 1000 ns pulses with a 45 °C temperature set point. Treatments were administered percutaneously via an electrode and grounding pad approach using an internally cooled electrode applicator. The exposed electrode region at the distal end of the applicator was set to either 0.5, 1.0, 1.5, or 2.0 cm. Ablation zones were assessed via ultrasound, contrast-enhanced CT, and gross pathology one week post-treatment. Cardiac safety was evaluated by measuring pre- and post-treatment serum Troponin levels. <b>Results:</b> All treatments were completed without adverse events. Troponin levels remained stable (pre: 0.249 ng/mL; post: 0.224 ng/mL), indicating no measurable cardiac injury. The 1.5 cm exposure length produced the largest and most consistent ablation volumes, with a mean volume of 12.8 ± 2.6 cm<sup>3</sup> and average dimensions of 3.7 × 2.7 cm in under 6 min. Increasing exposure length beyond 1.5 cm introduced greater variability and reduced treatment volumes. <b>Conclusions:</b> INSPIRE enables safe, large-volume, single-applicator ablation without a need for electrical pulse synchronization with R wave in cardiac rhythm. The 1.5 cm exposure length offers optimal balance between energy delivery and treatment consistency. These findings support further clinical investigation of INSPIRE for non-thermal ablation of inoperable tumors.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2025-09-02
DOI
https://doi.org/10.3390/cancers17172891
Primary Topic
Microbial Inactivation Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Nanosecond Pulse Irreversible Electroporation (INSPIRE): Impact of Exposed Electrode Length on Ablation Geometry in an In Vivo Liver Model

J. T. Darrow, M. Beecroft, Michael B. Sano, Kyle G. Mathews et al.
Cancers
Microbial Inactivation Methods
article

Integrated Nanosecond Pulse Irreversible Electroporation (INSPIRE): Impact of Exposed Electrode Length on Ablation Geometry in an In Vivo Liver Model

J. T. Darrow, M. Beecroft, Michael B. Sano, Kyle G. Mathews, Callie Fogle, Nathan C. Nelson, R. Williamson, David A. Gerber, Andrew Riordan, Jordan A. Fong, Logan Reeg, Alina C. Iuga, Alexia K. Cash
article en

Abstract

<b>Objectives:</b> There is a critical need for effective focal therapies for patients with inoperable or anatomically complex tumors where conventional ablation techniques pose high risk or are ineffective. Integrated Nanosecond Pulsed Irreversible Electroporation (INSPIRE) is a novel non-thermal ablation modality which uses real time temperature feedback during pulse delivery to safely treat tumors near critical structures. This study evaluated the impact of exposed electrode length on ablation zone size, reproducibility, and cardiac safety in a large animal model. <b>Methods:</b> INSPIRE treatments were performed in an in vivo healthy porcine liver model. All treatments administered 6000 V 1000 ns pulses with a 45 °C temperature set point. Treatments were administered percutaneously via an electrode and grounding pad approach using an internally cooled electrode applicator. The exposed electrode region at the distal end of the applicator was set to either 0.5, 1.0, 1.5, or 2.0 cm. Ablation zones were assessed via ultrasound, contrast-enhanced CT, and gross pathology one week post-treatment. Cardiac safety was evaluated by measuring pre- and post-treatment serum Troponin levels. <b>Results:</b> All treatments were completed without adverse events. Troponin levels remained stable (pre: 0.249 ng/mL; post: 0.224 ng/mL), indicating no measurable cardiac injury. The 1.5 cm exposure length produced the largest and most consistent ablation volumes, with a mean volume of 12.8 ± 2.6 cm<sup>3</sup> and average dimensions of 3.7 × 2.7 cm in under 6 min. Increasing exposure length beyond 1.5 cm introduced greater variability and reduced treatment volumes. <b>Conclusions:</b> INSPIRE enables safe, large-volume, single-applicator ablation without a need for electrical pulse synchronization with R wave in cardiac rhythm. The 1.5 cm exposure length offers optimal balance between energy delivery and treatment consistency. These findings support further clinical investigation of INSPIRE for non-thermal ablation of inoperable tumors.

CancersVol. 17(17)
University of North Carolina at Chapel Hill (US), North Carolina State University (US), Gradient (United States) (US), University of Cincinnati Medical Center (US)
North Carolina State University, National Institutes of Health, National Cancer Institute
Openalex Percentile: Top 74%
Microbial Inactivation Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.