A Polymer-Based CMUT Probe for Imaging the Spinal Cord in Rats

The ability of ultrasound imaging to deliver real-time visualization of tissue structures and surgical instruments can provide essential benefits in guiding medical interventions. In spinal cord injury research, small animal models are commonly used, but their size restricts the applicability of many standard ultrasound systems. Capacitive micromachined ultrasonic transducers (CMUTs) offer advantages over traditional piezoelectric transducers, including a smaller form factor, high design flexibility, and improved acoustic performance. CMUT structures made of polymers (polyCMUTs) can be produced cost-effectively and quickly, while potentially offering flexible, biocompatible transducers for next-generation ultrasound systems. This study introduces the first polyCMUT probe designed for imaging spinal cords in rats. A compact 11 MHz, 64 channel probe with a $12.9\times 6.5$ mm small tip was developed through a three-stage fabrication process, combining in-house manufactured polyCMUT arrays with electronics, integrated in a research imaging system. Performance evaluation included electrical impedance measurements, acoustic characterization, and in vitro and ex-vivo imaging. Quality analysis validated the stability of the fabrication process, demonstrating high yield and minimal variability, with a standard deviation in resonance frequency of less than 1%. The probe successfully visualized key anatomical structures like the central canal as well as real-time imaging of needle insertion into tissue. However, distinguishing between gray and white matter remained challenging due to limitations in frequency and bandwidth. This study demonstrates the potential of the polyCMUT technology for developing tailored ultrasound solutions. Future work will focus on optimizing high-frequency performance and advancing toward in vivo applications to provide meaningful tools in spinal cord injury research and therapeutic interventions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-09-02
DOI
https://doi.org/10.1109/tuffc.2025.3605440
Citations
1
Primary Topic
Nanoparticle-Based Drug Delivery
Type
article
Field-Weighted Citation Impact
0.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Polymer-Based CMUT Probe for Imaging the Spinal Cord in Rats

Jill Welsch, Edmond Cretu, Wolfram Tetzlaff, Martin Angerer et al.
1 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Nanoparticle-Based Drug Delivery
0.60
article

A Polymer-Based CMUT Probe for Imaging the Spinal Cord in Rats

Jill Welsch, Edmond Cretu, Wolfram Tetzlaff, Martin Angerer, Robert Rohling, Jianjun Lu, Ming Lu, Changqing Luo, W. Plunet
article en
1 citations

Abstract

The ability of ultrasound imaging to deliver real-time visualization of tissue structures and surgical instruments can provide essential benefits in guiding medical interventions. In spinal cord injury research, small animal models are commonly used, but their size restricts the applicability of many standard ultrasound systems. Capacitive micromachined ultrasonic transducers (CMUTs) offer advantages over traditional piezoelectric transducers, including a smaller form factor, high design flexibility, and improved acoustic performance. CMUT structures made of polymers (polyCMUTs) can be produced cost-effectively and quickly, while potentially offering flexible, biocompatible transducers for next-generation ultrasound systems. This study introduces the first polyCMUT probe designed for imaging spinal cords in rats. A compact 11 MHz, 64 channel probe with a $12.9\times 6.5$ mm small tip was developed through a three-stage fabrication process, combining in-house manufactured polyCMUT arrays with electronics, integrated in a research imaging system. Performance evaluation included electrical impedance measurements, acoustic characterization, and in vitro and ex-vivo imaging. Quality analysis validated the stability of the fabrication process, demonstrating high yield and minimal variability, with a standard deviation in resonance frequency of less than 1%. The probe successfully visualized key anatomical structures like the central canal as well as real-time imaging of needle insertion into tissue. However, distinguishing between gray and white matter remained challenging due to limitations in frequency and bandwidth. This study demonstrates the potential of the polyCMUT technology for developing tailored ultrasound solutions. Future work will focus on optimizing high-frequency performance and advancing toward in vivo applications to provide meaningful tools in spinal cord injury research and therapeutic interventions.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(11)
University of British Columbia Hospital (CA), University of British Columbia (CA), International Collaboration On Repair Discoveries (CA)
Openalex Percentile: Top 30%
Nanoparticle-Based Drug Delivery
0.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.